Bilateral spontaneous subluxation of scleral-fixated intraocular lenses
- PMID: 12498862
- DOI: 10.1016/s0886-3350(02)01372-x
Bilateral spontaneous subluxation of scleral-fixated intraocular lenses
Abstract
Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.