The serum digitalis concentration--does it diagnose digitalis toxicity?
- PMID: 1250314
- DOI: 10.1056/NEJM197604152941603
The serum digitalis concentration--does it diagnose digitalis toxicity?
Abstract
We propose that an investigation of the serum digitalis concentration as a test for digitalis toxicity should (1) study patients with similar toxic manifestations, (2) obtain control concentrations from nontoxic patients with symptoms suggesting toxicity, (3) define criteria for toxicity and nontoxicity, (4) select representative patients, (5) describe the study population and (6) analyze how much diagnostic information the serum digitalis concentration provides that cannot be inferred from other observations. To determine if available evidence validates the digitalis concentration as a test for toxicity 27 reports were reviewed. No investigation employed symptomatic controls. Of five studies most consistent with points 1-5 only three demonstrated higher mean serum digitalis concentrations in toxic patients. Whether knowledge of the digitalis concentrations was diagnostically more useful than knowledge of the digitalis dosage, renal function, serum potassium concentration and cardiac status was not determined in any study. The usefulness of the serum digitalis concentration as a test for digitalis toxicity is therefore not established.
Similar articles
-
[Clinical experiences with the serum digitalis concentration. 1006 radioimmunological determinations].Schweiz Med Wochenschr. 1977 Dec 10;107(49):1822-5. Schweiz Med Wochenschr. 1977. PMID: 929143 German.
-
[A questionnaire for early recognition of digitalis intoxication (author's transl)].Med Klin. 1978 Nov 24;73(47):1664-9. Med Klin. 1978. PMID: 723747 German.
-
[Serum concentration of digitalis glycosides as a therapeutic guide].Schweiz Med Wochenschr. 1976 Jul 3;106(27):909-11. Schweiz Med Wochenschr. 1976. PMID: 996509 German.
-
Serum digitalis measurements in the assessment of digitalis resistance and sensitivity.Am J Med. 1975 Apr;58(4):460-9. doi: 10.1016/0002-9343(75)90117-5. Am J Med. 1975. PMID: 1092161 Review.
-
Digitalis toxicity: epidemiology and clinical use of serum concentration measurements.Am J Med. 1975 Apr;58(4):470-6. doi: 10.1016/0002-9343(75)90118-7. Am J Med. 1975. PMID: 1092162 Review.
Cited by
-
Comparison of drug dosing methods.Clin Pharmacokinet. 1985 Jan-Feb;10(1):1-37. doi: 10.2165/00003088-198510010-00001. Clin Pharmacokinet. 1985. PMID: 3882303 Review.
-
The appropriate use of serum digoxin assay.Can Fam Physician. 1977 Oct;23:107-13. Can Fam Physician. 1977. PMID: 21304851 Free PMC article.
-
A standard approach to compiling clinical pharmacokinetic data.J Pharmacokinet Biopharm. 1981 Feb;9(1):59-127. doi: 10.1007/BF01059343. J Pharmacokinet Biopharm. 1981. PMID: 7014827
-
Interpretation of the serum digoxin concentration.Clin Pharmacokinet. 1977 May-Jun;2(3):205-19. doi: 10.2165/00003088-197702030-00005. Clin Pharmacokinet. 1977. PMID: 141993 Review.
-
Clinical pharmacokinetics of digoxin 1980.Clin Pharmacokinet. 1980 Mar-Apr;5(2):137-49. doi: 10.2165/00003088-198005020-00002. Clin Pharmacokinet. 1980. PMID: 6988136 Review. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources