Polymer refilling of presbyopic human lenses in vitro restores the ability to undergo accommodative changes
- PMID: 12506082
- DOI: 10.1167/iovs.02-0256
Polymer refilling of presbyopic human lenses in vitro restores the ability to undergo accommodative changes
Abstract
Purpose: Because presbyopia is thought to be accompanied by increased lens sclerosis this study was conducted to investigate whether refilling the capsule of the presbyopic human lens with a soft polymer would restore the ability of the lens to undergo accommodative changes.
Methods: Accommodative forces were applied to natural and refilled lenses by circumferential stretching through the ciliary body and zonular complex. Nine natural lenses and 10 refilled lenses from donors ranging in age from 17 to 60 years were studied. Two refill polymers with a different Young's modulus were used. The lens power was measured by a scanning laser ray-tracing technique, and lens diameter and lens thickness were measured simultaneously while the tension on the zonules was increased stepwise by outward pull on the ciliary body.
Results: In the natural lenses the older lenses were not able to undergo power changes with stretching of the ciliary body, whereas in the refilled lenses, all lenses showed power changes comparable to young, natural lenses. The refilled human lenses had a higher lens power than the age-matched natural lenses. The Young's modulus of the polymers influenced the lens power change when measured with the ciliary body diameter increased by 4 mm.
Conclusions: Refilling presbyopic lenses with a soft polymer enabled restoration of lens power changes with mechanical stretching. Because sclerosis of the lens is an important factor in human presbyopia, refilling the lens during lens surgery for cataract could enable restoration of clear vision and accommodation in human presbyopia.
Similar articles
-
Relation between injected volume and optical parameters in refilled isolated porcine lenses.Ophthalmic Physiol Opt. 2004 Nov;24(6):572-9. doi: 10.1111/j.1475-1313.2004.00238.x. Ophthalmic Physiol Opt. 2004. PMID: 15491485
-
Changes in lens stiffness due to capsular opacification in accommodative lens refilling.Exp Eye Res. 2015 May;134:148-54. doi: 10.1016/j.exer.2015.02.015. Epub 2015 Feb 19. Exp Eye Res. 2015. PMID: 25704214
-
Comparison of the behavior of natural and refilled porcine lenses in a robotic lens stretcher.Exp Eye Res. 2009 Mar;88(3):483-94. doi: 10.1016/j.exer.2008.10.021. Epub 2008 Nov 11. Exp Eye Res. 2009. PMID: 19041865
-
Lens refilling to restore accommodation.J Cataract Refract Surg. 2009 Feb;35(2):374-82. doi: 10.1016/j.jcrs.2008.10.054. J Cataract Refract Surg. 2009. PMID: 19185257 Review.
-
Accommodating intraocular lenses: a critical review of present and future concepts.Graefes Arch Clin Exp Ophthalmol. 2007 Apr;245(4):473-89. doi: 10.1007/s00417-006-0391-6. Epub 2006 Aug 30. Graefes Arch Clin Exp Ophthalmol. 2007. PMID: 16944188 Review.
Cited by
-
Long-term prevention of capsular opacification after lens-refilling surgery in a rabbit model.Acta Ophthalmol. 2019 Sep;97(6):e860-e870. doi: 10.1111/aos.14096. Epub 2019 Mar 22. Acta Ophthalmol. 2019. PMID: 30900825 Free PMC article.
-
Accommodative lens refilling in rhesus monkeys.Invest Ophthalmol Vis Sci. 2006 Jul;47(7):2976-84. doi: 10.1167/iovs.05-1346. Invest Ophthalmol Vis Sci. 2006. PMID: 16799042 Free PMC article.
-
Edinger-Westphal and pharmacologically stimulated accommodative refractive changes and lens and ciliary process movements in rhesus monkeys.Exp Eye Res. 2007 Feb;84(2):302-13. doi: 10.1016/j.exer.2006.10.003. Epub 2006 Nov 28. Exp Eye Res. 2007. PMID: 17137577 Free PMC article.
-
Hesperetin treatment attenuates glycation of lens proteins and advanced‑glycation end products generation.Mol Med Rep. 2023 May;27(5):103. doi: 10.3892/mmr.2023.12990. Epub 2023 Mar 31. Mol Med Rep. 2023. PMID: 36999595 Free PMC article.
-
Accommodation amplitudes after an accommodating intraocular lens refilling procedure: in vivo update.J Cataract Refract Surg. 2014 Feb;40(2):295-305. doi: 10.1016/j.jcrs.2013.06.028. J Cataract Refract Surg. 2014. PMID: 24461501 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources