Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Nov;3(11):665-72.

Continuous recording of dicrotic and pulse pressures during head-up tilting test: the vasodepressive profile. Preliminary data

Affiliations
  • PMID: 12506525

Continuous recording of dicrotic and pulse pressures during head-up tilting test: the vasodepressive profile. Preliminary data

Salvatore M Romano et al. Ital Heart J. 2002 Nov.

Abstract

Background: The aim of this study was to assess whether a non-invasive automatic evaluation of the pulse wave characteristics could provide clinical clues when monitoring the hemodynamic adjustments to head-up tilting.

Methods: A continuous assessment of the peripheral pulse wave characteristics (systolic, diastolic, dicrotic and pulse pressures) in 8 control subjects with a negative response to head-up tilting (60 degrees for 45 min) compared to 13 syncopal patients with a vasodepressive one was performed.

Results: Controls exhibited, when up-tilted, an increase in blood pressure as well as in the dicrotic and pulse pressures and no changes in heart rate. On the contrary, syncopal patients showed a progressive increase in heart rate associated with a progressive decrease in dicrotic pressure and a trend towards lower values of pulse pressure, but no changes in systolic pressure. Thereafter and until the pre-syncopal symptoms supervened, the systolic, diastolic and dicrotic pressures progressively declined. A decrease in dicrotic pressure mainly characterized the early vasodepressive response while its increase identified the negative one.

Conclusions: Our data, even though preliminary, strongly suggest that automatic hemodynamic evaluation is to be used in the clinical setting as a monitor of the sudden changes in blood pressure induced by head-up tilting. Furthermore, the dicrotic and pulse pressures, even those measured during the early phases of the test, should be considered as non-invasive parameters characterizing the vasodepressive response to head-up tilting.

PubMed Disclaimer