Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Jan 7;107(1):38-42.
doi: 10.1161/01.cir.0000047700.58683.a1.

TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions

Affiliations
Clinical Trial

TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions

Eberhard Grube et al. Circulation. .

Abstract

Background: The TAXUS NIRx stent (Boston Scientific Corp) provides local delivery of paclitaxel via a slow-release polymer coating. The TAXUS I trial was the first in-human experience evaluating safety and feasibility of the TAXUS NIRx stent system compared with bare NIR stents (control) (Boston Scientific Corp) for treatment of coronary lesions.

Methods and results: The TAXUS I trial was a prospective, double-blind, three-center study randomizing 61 patients with de novo or restenotic lesions (< or =12 mm) to receive a TAXUS (n=31) versus control (n=30) stent (diameter 3.0 or 3.5 mm). Demographics, lesion characteristics, clinical outcomes were comparable between the groups. The 30-day major adverse cardiac event (MACE) rate was 0% in both groups (P=NS). No stent thromboses were reported at 1, 6, 9, or 12 months. At 12 months, the MACE rate was 3% (1 event) in the TAXUS group and 10% (4 events in 3 patients) in the control group (P=NS). Six-month angiographic restenosis rates were 0% for TAXUS versus 10% for control (P=NS) patients. There were significant improvements in minimal lumen diameter (2.60+/-0.49 versus 2.19+/-0.65 mm), diameter stenosis (13.56+/-11.77 versus 27.23+/-16.69), and late lumen loss (0.36+/-0.48 versus 0.71+/-0.48 mm) in the TAXUS group (all P<0.01). No evidence of edge restenosis was seen in either group. Intravascular ultrasound analysis showed significant improvements in normalized neointimal hyperplasia in the TAXUS (14.8 mm3) group compared with the control group (21.6 mm3) (P<0.05).

Conclusions: In this feasibility trial, the TAXUS slow-release stent was well tolerated and showed promise for treatment of coronary lesions, with significant reductions in angiographic and intravascular ultrasound measures of restenosis.