Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Jan;19(1):54-61.
doi: 10.1053/jars.2003.50012.

Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results

Affiliations

Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results

Vladimir Senekovic et al. Arthroscopy. 2003 Jan.

Abstract

Purpose: Fractures of the tibial eminence can be treated arthroscopically. Fixation of the fracture is usually followed by temporary immobilization. The literature suggests that only anterograde fixation with cannulated screws and washer is considered stable enough to allow for immediate mobilization and weight bearing. The goal of this study was to evaluate the 5-year results of arthroscopic reductions and anterograde fixations of the tibial eminence fracture with cannulated screws.

Type of study: Retrospective study.

Methods: Thirty-two patients were treated arthroscopically for type II, III, and IV fractures of the intercondylar eminence of the tibia. The fragments were reduced and fixed with a cannulated screw or cannulated screw and washer. The intermeniscal ligament was involved in the fracture in 29 cases, and the anterior part of the medial meniscus was involved in 3 cases, requiring a temporary shift before reduction of the fragment. Arthrotomy was not performed for reduction or fixation of the fragment. All patients began continuous passive and active motion of the involved knee and were mobilized on crutches the day after the procedure. They were allowed immediate weight bearing. The patients were followed up for 16 to 69 months.

Results: Good therapeutic results were found at follow-up. Average value for KT-1000 testing was 1.1 mm; flexion deficit was 1.2 degrees; extension deficit, 0.6 degrees; and Lysholm score, 98.8. The average treatment duration was 12 weeks. There was one case of aseptic synovitis and no other complications. In all but 1 patient, the implants were removed.

Conclusions: Arthroscopic fixation of the fracture of the intercondylar eminence of the tibia with a cannulated screw or screw and washer is a simple, safe, reproducible, and effective procedure. The fixation is stable even in type IV fractures, so that immobilization is unnecessary.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources