Influence of leg position and environmental temperature on segmental volume expansion during venous occlusion plethysmography
- PMID: 12529168
- DOI: 10.1042/CS20020257
Influence of leg position and environmental temperature on segmental volume expansion during venous occlusion plethysmography
Abstract
Blood flow determinations by venous occlusion plethysmography applying the strain-gauge technique are frequently used. A problem with the strain-gauge technique is that the relationship between venous volume and transmural pressure is not linear and, furthermore, changes with the sympathetic tone. The present study tests the hypothesis that these factors lead to a redistribution of venous blood, which may impair the accuracy of the technique. The relative volume expansion rates of four leg segments were studied with the leg in different positions and at disparate temperatures, thereby inducing varying venous pressures and sympathetic tone ( n =6). With elevated leg and relaxed veins (at 50 degrees C), the distal thigh showed a relatively low expansion rate (25.8+/-4.5 ml.min(-1).l(-1)), whereas values in the calf segments were higher (34.5-39.0 ml.min(-1).l(-1)). With lower initial transmural pressure, calf segments can increase their volume much more during occlusion compared with the distal thigh. In a higher transmural pressure region (lowered leg), the difference in compliance between limb segments is less. In this case, compliance and volume expansion rate was higher in the distal thigh (14.2, 13.5 and 22.2 ml.min(-1).l(-1) at 10, 20 and 50 degrees C respectively) than in the calf segments (for the distal calf: 6.4, 7.7 and 16.2 ml.min(-1).l(-1) respectively). There was a significant interaction ( P <0.001) between temperature and leg position, indicating a higher degree of sympathetic vasoactivity in the calf. It is concluded that blood flow determination by strain-gauge plethysmography is less accurate, due to a potential redistribution of the venous blood. Therefore possible influences of variations in sympathetic tone and venous pressure must be considered even in intra-individual comparisons, especially in interventional studies.
Similar articles
-
Alterations in forearm position and environmental temperature influences the segmental volume expansion during venous occlusion plethysmography--special attention on hand circulation.Clin Physiol Funct Imaging. 2009 Sep;29(5):376-81. doi: 10.1111/j.1475-097X.2009.00883.x. Epub 2009 Jun 11. Clin Physiol Funct Imaging. 2009. PMID: 19522855
-
Contrasting neurovascular findings in chronic orthostatic intolerance and neurocardiogenic syncope.Clin Sci (Lond). 2003 Apr;104(4):329-40. Clin Sci (Lond). 2003. PMID: 12653674
-
Calf venous compliance measured with head-up tilt equals supine calf compliance.J Gravit Physiol. 1995;2(1):P21-2. J Gravit Physiol. 1995. PMID: 11538917
-
[Disorders of venous blood flow during surgery and the postoperative period as a pathomechanism of venous thrombosis of the legs].Z Gesamte Inn Med. 1984 Sep 1;39(17):406-14. Z Gesamte Inn Med. 1984. PMID: 6390996 Review. German.
-
Optimal methods to assess the deep venous system in the lower limb.Acta Chir Scand Suppl. 1990;555:175-85. Acta Chir Scand Suppl. 1990. PMID: 2195823 Review. No abstract available.
Cited by
-
Gravity, the hydrostatic indifference concept and the cardiovascular system.Eur J Appl Physiol. 2011 Feb;111(2):163-74. doi: 10.1007/s00421-010-1646-9. Epub 2010 Sep 21. Eur J Appl Physiol. 2011. PMID: 20857139 Review.
-
Venous occlusion plethysmography versus Doppler ultrasound in the assessment of leg blood flow during calf exercise.Eur J Appl Physiol. 2011 Aug;111(8):1889-900. doi: 10.1007/s00421-010-1819-6. Epub 2011 Jan 14. Eur J Appl Physiol. 2011. PMID: 21234593 Clinical Trial.
-
Measurement of skeletal muscle perfusion during postischemic reactive hyperemia using contrast-enhanced MRI with a step-input function.Magn Reson Med. 2005 Aug;54(2):289-98. doi: 10.1002/mrm.20535. Magn Reson Med. 2005. PMID: 16032661 Free PMC article.
-
Peripheral arterial disease assessment: wall, perfusion, and spectroscopy.Top Magn Reson Imaging. 2007 Oct;18(5):357-69. doi: 10.1097/rmr.0b013e31815d064c. Top Magn Reson Imaging. 2007. PMID: 18025990 Free PMC article.
-
Calf muscle perfusion at peak exercise in peripheral arterial disease: measurement by first-pass contrast-enhanced magnetic resonance imaging.J Magn Reson Imaging. 2007 May;25(5):1013-20. doi: 10.1002/jmri.20899. J Magn Reson Imaging. 2007. PMID: 17410566 Free PMC article.
Publication types