Interobserver variability in coronary angiography
Abstract
Four experienced coronary angiographers (two radiologists and two cardiologists) independently assessed the location and degree of coronary artery stenosis, and the location and degree of left ventricular wall motion abnormalities in 20 coronary angiograms. Marked interobserver variability was noted in quantifying percent coronary artery stenosis and degree of left ventricular wall motion abnormalities. For example, in only 13/20 (65%) of the coronary angiograms did all observers agree about the significance of a stenosis (defined as greater than 50% in diameter luminal narrowing) in the proximal or mid left anterior descending coronary artery. In 3/20 (15%) angiograms there was disagreement by at least one observer about the significance of lesions noted in the main left coronary artery. The ventricle was divided into five segments and the degree of wall motion abnormality graded into six categories of increasing severity from normal to dyskinesis. There was a 42% mean disagreement among all four observers where a disagreement between observers was defined as any difference in grading wall motion abnormalities. Interobserver variability reveals a significant limitation of coronary angiography.
Similar articles
-
Accuracy and interobserver variability of coronary cineangiography: a comparison with postmortem evaluation.J Am Coll Cardiol. 1984 May;3(5):1145-54. doi: 10.1016/s0735-1097(84)80171-0. J Am Coll Cardiol. 1984. PMID: 6707366
-
Prediction of coronary artery disease by left ventricular regional wall motion abnormalities in patients with stenosis of the aortic valve.Br Heart J. 1987 Mar;57(3):237-41. doi: 10.1136/hrt.57.3.237. Br Heart J. 1987. PMID: 3566981 Free PMC article.
-
Observer agreement in evaluating coronary angiograms.Circulation. 1975 Dec;52(6):979-86. doi: 10.1161/01.cir.52.6.979. Circulation. 1975. PMID: 1102142 Clinical Trial.
-
Asynchronous left ventricular wall motion early after coronary thrombosis.Br Heart J. 1986 Jan;55(1):4-13. doi: 10.1136/hrt.55.1.4. Br Heart J. 1986. PMID: 3947480 Free PMC article.
-
Interobserver Variability of Coronary Stenosis Characterized by Coronary Angiography: A Single-Center (Toronto General Hospital) Retrospective Chart Review by Staff Cardiologists.Vasc Health Risk Manag. 2024 Aug 13;20:359-368. doi: 10.2147/VHRM.S431612. eCollection 2024. Vasc Health Risk Manag. 2024. PMID: 39157424 Free PMC article.
Cited by
-
Requirements on resolution of digital imaging equipment in the cardiac catheterization laboratory.Int J Card Imaging. 1988;3(2-3):111-6. doi: 10.1007/BF01814883. Int J Card Imaging. 1988. PMID: 3171239
-
Detection of right-coronary-artery disease using stress thallium scintigraphy: importance of considering the right ventricle.Eur J Nucl Med. 1986;11(9):336-40. doi: 10.1007/BF00253297. Eur J Nucl Med. 1986. PMID: 3956526
-
Do pediatric intensivists and radiologists concur on the interpretation of chest radiographs?Crit Care. 1998;2(2):67-72. doi: 10.1186/cc128. Crit Care. 1998. PMID: 11056712 Free PMC article.
-
Algorithm effects on computerized vessel analysis from digitized cine film and a new method of generating the centerline of a vessel.Int J Card Imaging. 1994 Mar;10(1):53-60. doi: 10.1007/BF01151581. Int J Card Imaging. 1994. PMID: 8021531
-
A new method for automatic identification of coronary arteries in standard biplane angiograms.Int J Card Imaging. 1994 Dec;10(4):253-61. doi: 10.1007/BF01137716. Int J Card Imaging. 1994. PMID: 7722346
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical