Abstract
This study investigated the effect of finishing/polishing techniques on the microleakage of resin-modified glass ionomer restorations. Class V preparations were made on the buccal and lingual/palatal surfaces of freshly extracted teeth. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]) according to manufacturers' instructions. Immediately after light-polymerization, gross finishing was done with eight-fluted tungsten carbide burs. The teeth were then randomly divided into four groups and finishing/polishing was done with one of the following systems: (a) Robot Carbides (RC); (b) Super-Snap system (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each material-finishing/polishing system combination was eight. After finishing/polishing, the teeth were stored in distilled water at 37 degrees C for one week. The root apices were then sealed with acrylic and two coats of varnish was applied 1 mm beyond the restoration margins. The teeth were subsequently subjected to dye penetration testing (0.5% basic fuchsin), sectioned and scored. Data was analyzed using Kruskal-Wallis and Mann-Whitney U tests at a significance level of 0.05. Results of statistical analysis were as follows: Enamel margins: PF-OG<SS; FT-OG<RC; Dentin margins: PF-no significant difference; FT-OG & CS<RC. Regardless of the finishing/polishing technique, leakage at dentin margins was significantly greater than at enamel margins for FT. For PF, no significant difference in leakage scores was observed between dentin and enamel with the exception of finishing/polishing with OG. FT restorations had significantly less enamel and dentin leakage than PF restorations when treated with OG. The effect of finishing/polishing techniques on microleakage was both tissue and material dependent.
Similar articles
-
Effects of instrumentation time on microleakage of resin-modified glass ionomer cements.Oper Dent. 2003 Jan-Feb;28(1):47-52. Oper Dent. 2003. PMID: 12540118 Clinical Trial.
-
Surface texture of resin-modified glass ionomer cements: effects of finishing/polishing systems.Oper Dent. 2002 Jul-Aug;27(4):381-6. Oper Dent. 2002. PMID: 12120776 Clinical Trial.
-
Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials.J Dent. 2000 Jul;28(5):367-73. doi: 10.1016/s0300-5712(99)00075-5. J Dent. 2000. PMID: 10785304
-
Review: finishing and polishing procedures of (resin-modified) glass ionomers and compomers in paediatric dentistry.Eur Arch Paediatr Dent. 2007 Mar;8(1):22-8. doi: 10.1007/BF03262566. Eur Arch Paediatr Dent. 2007. PMID: 17394887 Review.
-
Air polishing: a comprehensive review of the literature.J Dent Hyg. 1998 Summer;72(3):47-56. J Dent Hyg. 1998. PMID: 9693568 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous