Use of acetylene breathing to determine cardiac output in young and older adults

Affiliations
Clinical Trial

Use of acetylene breathing to determine cardiac output in young and older adults

Christopher Bell et al. Med Sci Sports Exerc. 2003 Jan.

Abstract

Purpose: The aims of this investigation were: 1). to establish the day-to-day reproducibility of open-circuit acetylene breathing for measuring exercise cardiac output (Q(c)) in young and older adults; and 2). to compare estimates of Q(c) from open-circuit acetylene breathing with estimates of Q(c) from previously established closed-circuit acetylene rebreathing.

Methods: Twenty men (10 young: 28 +/- 1 yr; 10 older: 61 +/- 1 yr (mean +/- SE)) performed cycle ergometry exercise on 3 separate days. Q(c) was estimated using open-circuit acetylene breathing on 2 d, and closed-circuit acetylene rebreathing on 1 d.

Results: Open-circuit acetylene breathing was highly reproducible (young: standard error of measurement (SEM) = 1.52 L.min (-1) limits of agreement (LOA) = 0.2 +/- 4.2 L.min (-1), coefficient of variation 6% < CV < 8%, day 2 = (0.9 x day 1) + 2.4, r = 0.90, P< 0.001, r (2)= 0.82; older: SEM = 0.94 L.min (-1), LOA = 0.1 +/- 2.8 L.min (-1), 4% < CV < 10%, day 2 = (1.0 x day 1) + 0, r = 0.91, < 0.001, r(2) = 0.82). Estimates of Q(c) from open-circuit acetylene breathing demonstrated good agreement with closed-circuit acetylene rebreathing (young: SEM = 1.52 L.min (-1), LOA = 0.9 +/- 4.4 L.min (-1), 5% < CV < 10%, open-circuit = (1.0 x closed-circuit) + 1.5, r = 0.89, < 0.001, r (2) = 0.79; older: SEM = 1.13 L.min (-1), LOA = 0.1 +/- 3.2 L.min (-1), 5% < CV < 9%, open-circuit = (0.9 x closed-circuit) + 1.6, r = 0.88, < 0.001, r(2) = 0.78).

Conclusion: These results demonstrate that open-circuit acetylene breathing provides reproducible measurements of Q(c) during exercise that demonstrate good agreement with values obtained from the acetylene rebreathing procedure in young and older healthy men.