Measurement of refractive errors in young myopes using the COAS Shack-Hartmann aberrometer
- PMID: 12553539
- DOI: 10.1097/00006324-200301000-00003
Measurement of refractive errors in young myopes using the COAS Shack-Hartmann aberrometer
Abstract
Purpose: To evaluate the Complete Ophthalmic Analysis System (COAS; WaveFront Science) for accuracy, repeatability, and instrument myopia when measuring myopic refractive errors.
Methods: We measured the refractive errors of 20 myopic subjects (+0.25 to -10 D sphere; 0 to -1.75 D cylinder) with a COAS, a phoropter, and a Nidek ARK-2000 autorefractor. Measurements were made for right and left eyes, with and without cycloplegia, and data were analyzed for large and small pupils. We used the phoropter refraction as our estimate of the true refractive error, so accuracy was defined as the difference between phoropter refraction and that of the COAS and autorefractor. Differences and means were computed using power vectors, and accuracy was summarized in terms of mean vector and mean spherocylindrical power errors. To assess repeatability, we computed the mean vector deviation for each of five measurements from the mean power vector and computed a coefficient of repeatability. Instrument myopia was defined as the difference between cycloplegic and noncycloplegic refractions for the same eyes.
Results: Without cycloplegia, both the COAS and autorefractor had mean power vector errors of 0.3 to 0.4 D. Cycloplegia improved autorefractor accuracy by 0.1 D, but COAS accuracy remained the same. For large pupils, COAS accuracy was best when Zernike mode Z4(0) (primary spherical aberration) was included in the computation of sphere power. COAS repeatability was slightly better than autorefraction repeatability. Mean instrument myopia for the COAS was not significantly different from zero.
Conclusions: When measuring myopes, COAS accuracy, repeatability, and instrument myopia were similar to those of the autorefractor. Error margins for both were better than the accuracy of subjective refraction. We conclude that in addition to its capability to measure higher-order aberrations, the COAS can be used as a reliable, accurate autorefractor.
Similar articles
-
Evaluation of a clinical aberrometer for lower-order accuracy and repeatability, higher-order repeatability, and instrument myopia.Optometry. 2005 Aug;76(8):461-72. doi: 10.1016/j.optm.2005.07.006. Optometry. 2005. PMID: 16150413
-
An evaluation of the Bausch & Lomb Zywave aberrometer.Clin Exp Optom. 2009 May;92(3):238-45. doi: 10.1111/j.1444-0938.2009.00360.x. Clin Exp Optom. 2009. PMID: 19469012 Free PMC article. Clinical Trial.
-
Comparison of aberrometer and autorefractor measures of refractive error in children.Optom Vis Sci. 2006 Nov;83(11):811-7. doi: 10.1097/01.opx.0000238708.74276.6c. Optom Vis Sci. 2006. PMID: 17106401
-
Repeatability and validity of Zywave aberrometer measurements.J Cataract Refract Surg. 2002 Dec;28(12):2135-41. doi: 10.1016/s0886-3350(02)01333-0. J Cataract Refract Surg. 2002. PMID: 12498848
-
Principles of Hartmann-Shack aberrometry.J Refract Surg. 2000 Sep-Oct;16(5):S563-5. doi: 10.3928/1081-597X-20000901-14. J Refract Surg. 2000. PMID: 11019873 Review. No abstract available.
Cited by
-
Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.J Optom. 2015 Jul-Sep;8(3):206-18. doi: 10.1016/j.optom.2015.01.005. Epub 2015 Feb 7. J Optom. 2015. PMID: 25662364 Free PMC article.
-
Comparative Study of Refraction between Wave Front-Based Refraction and Autorefraction without and with Cycloplegia in Children and Adolescents.Children (Basel). 2022 Jan 9;9(1):88. doi: 10.3390/children9010088. Children (Basel). 2022. PMID: 35053713 Free PMC article.
-
Subjective versus objective refraction in healthy young adults.BMC Ophthalmol. 2024 Feb 20;24(1):79. doi: 10.1186/s12886-024-03340-w. BMC Ophthalmol. 2024. PMID: 38378511 Free PMC article.
-
Advancing Digital Workflows for Refractive Error Measurements.J Clin Med. 2020 Jul 12;9(7):2205. doi: 10.3390/jcm9072205. J Clin Med. 2020. PMID: 32664689 Free PMC article.
-
Higher-order aberrations and visual acuity after LASEK.Int Ophthalmol. 2008 Aug;28(4):269-73. doi: 10.1007/s10792-007-9124-z. Epub 2007 Aug 31. Int Ophthalmol. 2008. PMID: 17763828