Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers
- PMID: 12562376
- DOI: 10.1034/j.1600-0501.2003.140118.x
Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers
Abstract
The accuracy of surgical drilling guides was assessed for placement of zygoma implants. Six zygoma fixtures of length 45 mm (Nobel Biocare, Göteborg, Sweden) were placed in three formalin-fixed human cadavers using surgical drilling guides. The fabrication of these custom-made drilling guides was based on three-dimensional computerized tomography (3D-CT) data for the maxillary-zygomatic complex. The installation of the implants was simulated preoperatively using an adopted 3D-CT planning system. In addition, anatomical measurements of the zygomatic bone were performed on the 3D images. The preoperative CT images were then matched with postoperative ones in order to assess the deviation between the planned and installed implants. The angle between the planned and actually placed implants was < 3 degrees in four out of six cases. The largest deviation found at the exit point of one of the six implants was 2.7 mm. The present study showed that the use of surgical drilling guides should be encouraged for zygoma implant placement because of the lengths of the implants involved and the anatomical intricacies of the region.
Similar articles
-
[The installation of zygomatic implants and drilling guide].Zhonghua Kou Qiang Yi Xue Za Zhi. 2006 Mar;41(3):140-3. Zhonghua Kou Qiang Yi Xue Za Zhi. 2006. PMID: 16777017 Chinese.
-
Accuracy evaluation of computed tomography-derived stereolithographic surgical guides in zygomatic implant placement in human cadavers.J Oral Implantol. 2010;36(5):345-55. doi: 10.1563/AAID-JOI-D-09-00074. Epub 2010 Jun 14. J Oral Implantol. 2010. PMID: 20545538
-
Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study.Int J Oral Maxillofac Surg. 2003 Feb;32(1):7-14. doi: 10.1054/ijom.2002.0337. Int J Oral Maxillofac Surg. 2003. PMID: 12653226
-
Zygomatic implants: indications, techniques and outcomes, and the zygomatic success code.Periodontol 2000. 2014 Oct;66(1):41-58. doi: 10.1111/prd.12038. Periodontol 2000. 2014. PMID: 25123760 Review.
-
Static Zygomatic Guides: Digital ZAGA Concept.Oral Maxillofac Surg Clin North Am. 2025 May;37(2):383-401. doi: 10.1016/j.coms.2024.11.006. Epub 2025 Jan 10. Oral Maxillofac Surg Clin North Am. 2025. PMID: 39799051 Review.
Cited by
-
Zygomatic implants: a critical review of the surgical techniques.Oral Maxillofac Surg. 2013 Mar;17(1):1-9. doi: 10.1007/s10006-012-0316-y. Epub 2012 Jan 25. Oral Maxillofac Surg. 2013. PMID: 22274763 Review.
-
Retrospective analysis of the predictability of using three-dimensional models for preoperative planning of the length of zygomatic implants.Oral Maxillofac Surg. 2023 Mar;27(1):53-58. doi: 10.1007/s10006-022-01047-0. Epub 2022 Feb 15. Oral Maxillofac Surg. 2023. PMID: 35166998
-
Use of three points to determine the accuracy of guided implantation.PLoS One. 2019 Dec 3;14(12):e0225823. doi: 10.1371/journal.pone.0225823. eCollection 2019. PLoS One. 2019. PMID: 31794595 Free PMC article.
-
In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants.Imaging Sci Dent. 2012 Sep;42(3):139-46. doi: 10.5624/isd.2012.42.3.139. Epub 2012 Sep 21. Imaging Sci Dent. 2012. PMID: 23071963 Free PMC article.
-
Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography.Clin Oral Investig. 2010 Jun;14(3):303-10. doi: 10.1007/s00784-009-0291-3. Epub 2009 Jun 9. Clin Oral Investig. 2010. PMID: 19506922 Free PMC article.