Determination of mutagenic 3-nitrobenzanthrone in diesel exhaust particulate matter by three-dimensional high-performance liquid chromatography
- PMID: 12572801
- DOI: 10.1039/b210174b
Determination of mutagenic 3-nitrobenzanthrone in diesel exhaust particulate matter by three-dimensional high-performance liquid chromatography
Abstract
Mutagenic 3-nitrobenzanthrone was determined in diesel exhaust particulate matter by three-dimensional high-performance liquid chromatography. Nitrophenylethyl, C18 and pyrenylethyl stationary phases were used as the first, second and third dimensions, respectively. Methanol was used as a mobile phase for the first and second dimensions, and dichloromethane was used for the third. Each column was coupled by a 6-port valve with a concentrator column. Effluent from the third dimensional column was detected by a photodiode array detector. The calibration graph showed good linearity in the range of 1-1000 ng ml(-1), and the detection limit (S/N = 3) was 1 ng ml(-1) 3-Nitrobenzanthrone could be detected within 45 min without the requirement of a clean-up procedure. 3-Nitrobenzanthrone in diesel exhaust particulate matter was detected in the range of 27-56 pg mg(-1) extract (n = 3).
Similar articles
-
Determination of 3-nitrobenzanthrone in surface soil by normal-phase high-performance liquid chromatography with fluorescence detection.J Chromatogr A. 2003 Apr 11;992(1-2):101-7. doi: 10.1016/s0021-9673(03)00279-6. J Chromatogr A. 2003. PMID: 12735466
-
Determination of airborne particle-associated benz[a]anthracene-7,12-quinone using high-performance liquid chromatography with in-line reduction and fluorescence detection.J Chromatogr A. 2009 Sep 25;1216(39):6758-61. doi: 10.1016/j.chroma.2009.08.009. Epub 2009 Aug 11. J Chromatogr A. 2009. PMID: 19709663
-
Assessment of 3-nitrobenzanthrone reductase activity in mammalian tissues by normal-phase HPLC with fluorescence detection.J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Sep 25;824(1-2):229-37. doi: 10.1016/j.jchromb.2005.07.016. J Chromatogr B Analyt Technol Biomed Life Sci. 2005. PMID: 16095987
-
Determination of polycyclic aromatic hydrocarbons in diesel exhaust particulate matter and diesel fuel oil.J Chromatogr. 1984 Nov 16;312:247-59. doi: 10.1016/s0021-9673(01)92779-7. J Chromatogr. 1984. PMID: 6084667
-
3-Nitrobenzanthrone, a potential human cancer hazard in diesel exhaust and urban air pollution: a review of the evidence.Mutagenesis. 2005 Nov;20(6):399-410. doi: 10.1093/mutage/gei057. Epub 2005 Sep 30. Mutagenesis. 2005. PMID: 16199526 Review.
Cited by
-
Occurrence of the potent mutagens 2- nitrobenzanthrone and 3-nitrobenzanthrone in fine airborne particles.Sci Rep. 2019 Jan 9;9(1):1. doi: 10.1038/s41598-018-37186-2. Sci Rep. 2019. PMID: 30626917 Free PMC article.
-
Mechanism of Error-Free Bypass of the Environmental Carcinogen N-(2'-Deoxyguanosin-8-yl)-3-aminobenzanthrone Adduct by Human DNA Polymerase η.Chembiochem. 2016 Nov 3;17(21):2033-2037. doi: 10.1002/cbic.201600420. Epub 2016 Sep 13. Chembiochem. 2016. PMID: 27556902 Free PMC article.
-
Base-Displaced Intercalated Structure of the N-(2'-Deoxyguanosin-8-yl)-3-aminobenzanthrone DNA Adduct.Chem Res Toxicol. 2015 Dec 21;28(12):2253-66. doi: 10.1021/acs.chemrestox.5b00277. Epub 2015 Dec 7. Chem Res Toxicol. 2015. PMID: 26641105 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources