Partial CO2 rebreathing cardiac output--operating principles of the NICO system
- PMID: 12578034
- DOI: 10.1023/a:1009981313076
Partial CO2 rebreathing cardiac output--operating principles of the NICO system
Abstract
The partial rebreathing method of cardiac output estimation is reviewed with a particular focus on its application for continuous monitoring, rebreathing and implementations and from both a historical and technical perspective. The assumptions of the method are discussed as well as the various implementations. The NICO monitor and rebreathing valve are described from a functional view. The clinical data including (a) comparisons between bolus thermodilution and continuous thermodilution in patients in the OR setting, (b) comparisons to continuous thermodilution with both the Baxter and Abbott continuous cardiac output devices and (c) comparison between different means of shunt correction are presented. Compared to conventional cardiac output methods, the partial CO2 rebreathing technique is non-invasive, can easily be automated and can provide real-time and continuous cardiac output monitoring. Taking advantage of modern sophisticated sensor and signal processing technology and integrating multiple monitored physiological variables the NICO monitor is the first commercially available cardiac output system making use of the partial rebreathing of CO2.
Similar articles
-
Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.J Clin Monit Comput. 2000;16(5-6):361-74. doi: 10.1023/a:1011403717822. J Clin Monit Comput. 2000. PMID: 12580219
-
[Measurement of cardiac output after cardiac surgery: validation of a partial carbon dioxide rebreathing (NICO) system in comparison with continuous thermodilution with a pulmonary artery catheter].Rev Esp Anestesiol Reanim. 2005 May;52(5):256-62. Rev Esp Anestesiol Reanim. 2005. PMID: 15968903 Spanish.
-
Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow.Crit Care Med. 1997 Apr;25(4):675-83. doi: 10.1097/00003246-199704000-00020. Crit Care Med. 1997. PMID: 9142035
-
Noninvasive monitoring cardiac output using partial CO(2) rebreathing.Crit Care Clin. 2010 Apr;26(2):383-92, table of contents. doi: 10.1016/j.ccc.2009.12.002. Crit Care Clin. 2010. PMID: 20381727 Review.
-
Cardiac output monitoring: a contemporary assessment and review.Crit Care Med. 2015 Jan;43(1):177-85. doi: 10.1097/CCM.0000000000000608. Crit Care Med. 2015. PMID: 25251758 Review.
Cited by
-
Mechanical Ventilator Parameter Estimation for Lung Health through Machine Learning.Bioengineering (Basel). 2021 May 7;8(5):60. doi: 10.3390/bioengineering8050060. Bioengineering (Basel). 2021. PMID: 34067153 Free PMC article.
-
Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.J Clin Monit Comput. 2011 Dec;25(6):397-404. doi: 10.1007/s10877-011-9318-9. Epub 2011 Nov 6. J Clin Monit Comput. 2011. PMID: 22057246
-
Pulmonary blood flow (cardiac output) and the effective lung volume determined from a short breath hold using the differential Fick method.J Clin Monit Comput. 2002 Jul;17(5):313-21. doi: 10.1023/a:1021232624767. J Clin Monit Comput. 2002. PMID: 12546265
-
Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.J Clin Monit Comput. 2000;16(5-6):361-74. doi: 10.1023/a:1011403717822. J Clin Monit Comput. 2000. PMID: 12580219
-
Cardiac output estimation using ballistocardiography: a feasibility study in healthy subjects.Sci Rep. 2024 Jan 19;14(1):1671. doi: 10.1038/s41598-024-52300-3. Sci Rep. 2024. PMID: 38238507 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources