The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs
- PMID: 12578047
- DOI: 10.1023/a:1009950731297
The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs
Abstract
Objective: To clarify the relationship between blood pressure and pulse wave transit time at the peripheral artery from the R wave of the electrocardiogram (m-PWTT), the effects of cardiovascular interventions on this relationship was evaluated.
Methods: Ten mongrel dogs were anesthetized by isoflurane inhalation, and catheter tip pressure transducers were inserted into the ascending aorta and at the bifurcation of abdominal aorta to measure central and peripheral pulse wave arrival. Pulse wave arrival at the ascending aorta from the R wave represents pre-ejection period (PEP) and pulse wave arrival between the ascending aorta and bifurcation of aorta represents pulse wave transit time (PWTT), thus m-PWTT = PEP + PWTT. Hypertension was induced by the continuous infusion of dobutamine and phenylephrine, and hypotension was induced by deepening isoflurane anesthesia, acute blood loss and nitroglycerine infusion. The relationship between timing components (PWTT, PEP, and m-PWTT) and blood pressure was recorded and analyzed by using the least squares method.
Results: The relationship between timing components (PWTT, PEP and, m-PWTT) and blood pressure was significant and highly correlated. When the change in blood pressure was due to the myocardial contractility, such as after dobutamine infusion, the relationship between all timing components and blood pressure was consistent and negative. However, when the change in blood pressure was due to the vasoactive agents, such as phenylephrine, the relationship between timing components and blood pressure was dependent on the reflex change in PEP.
Conclusions: Change in m-PWTT is a good parameter to predict blood pressure changes, although the absolute blood pressure value cannot be obtained.
Similar articles
-
Ability of pulse wave transit time to detect changes in stroke volume and to estimate cardiac output compared to thermodilution technique in isoflurane-anaesthetised dogs.Vet Anaesth Analg. 2017 Sep;44(5):1057-1067. doi: 10.1016/j.vaa.2016.11.014. Epub 2017 Apr 26. Vet Anaesth Analg. 2017. PMID: 29029934
-
A novel continuous cardiac output monitor based on pulse wave transit time.Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:2853-6. doi: 10.1109/IEMBS.2010.5626343. Annu Int Conf IEEE Eng Med Biol Soc. 2010. PMID: 21095971
-
Impact of dopamine or dobutamine infusions on cardiovascular variables after rapid blood loss and volume replacement during isoflurane-induced anesthesia in dogs.Am J Vet Res. 2006 Jul;67(7):1121-30. doi: 10.2460/ajvr.67.7.1121. Am J Vet Res. 2006. PMID: 16817731 Clinical Trial.
-
Influence of catecholamines at different dosages on the function of the LiDCO sensor in isoflurane anesthetized horses.J Vet Emerg Crit Care (San Antonio). 2017 Nov;27(6):651-657. doi: 10.1111/vec.12672. Epub 2017 Oct 24. J Vet Emerg Crit Care (San Antonio). 2017. PMID: 29064159
-
Effects of dobutamine, dopamine, phenylephrine and noradrenaline on systemic haemodynamics and intestinal perfusion in isoflurane anaesthetised horses.Equine Vet J. 2018 Jan;50(1):104-110. doi: 10.1111/evj.12721. Epub 2017 Aug 30. Equine Vet J. 2018. PMID: 28710899 Clinical Trial.
Cited by
-
A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors.J Clin Monit Comput. 2004 Dec;18(5-6):313-20. doi: 10.1007/s10877-005-2452-5. J Clin Monit Comput. 2004. PMID: 15957621 Clinical Trial.
-
The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm.J Clin Monit Comput. 2012 Dec;26(6):465-71. doi: 10.1007/s10877-012-9384-7. Epub 2012 Aug 2. J Clin Monit Comput. 2012. PMID: 22854918 Free PMC article.
-
Evaluation of the estimated continuous cardiac output monitoring system in adults and children undergoing kidney transplant surgery: a pilot study.J Clin Monit Comput. 2014 Feb;28(1):95-9. doi: 10.1007/s10877-013-9501-2. Epub 2013 Aug 21. J Clin Monit Comput. 2014. PMID: 23963774
-
Factors Associated with Variability in Pulse Wave Transit Time Using Pulse Oximetry: A Retrospective Study.J Clin Med. 2022 Jul 7;11(14):3963. doi: 10.3390/jcm11143963. J Clin Med. 2022. PMID: 35887725 Free PMC article.
-
Comparative evaluation of stroke volume variation measured by pulse wave transit time and arterial pressure wave.Technol Health Care. 2024;32(2):651-662. doi: 10.3233/THC-220849. Technol Health Care. 2024. PMID: 37483029 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous