[Interstitial T1-weighted MR lymph fistulography with Gadomer-17 in an experimental animal model]
- PMID: 12584631
- DOI: 10.1055/s-2003-37231
[Interstitial T1-weighted MR lymph fistulography with Gadomer-17 in an experimental animal model]
Abstract
Purpose: To visualize and localize fistulas of the thoracic duct with interstitial T 1 -weighted MR lymphography using Gadomer-17.
Materials and methods: In 10 domestic pigs, leaks of the thoracic duct were created surgically or interventional-radiologically. The lymphatic leakage was located within the abdominal portion of the thoracic duct in 5 pigs, within the thoracic portion of the thoracic duct in 3 pigs, and in both, abdominal and thoracic portions of the thoracic duct, in 2 pigs. Subsequently, 10 micro mol/kg KG Gadomer-17 (1.5-1.8 ml) was administered interstitially in both hind legs of the animals. MR lymphography was performed with a 1.5 T MR unit using two different 3D gradient echo sequences before and 10 - 90 minutes after administration of contrast material.
Results: Leaks within the abdominal portion of the thoracic duct were directly visible as opacified fistulas. Indirect signs of active lymphatic fistulas were increasing extravasations of contrast material and free abdominal fluid. The 3D gradient echo sequence with the highest planar resolution (TR = 8,7 - 8,8 ms, TE = 4,2 - 4,3 ms, FA = 40 degrees, matrix size = 327 x 512) was best suited for distinct delineation of the lymphatic system and detailed demonstration of the thoracic duct fistulas. Intrathoracic leaks could not be demonstrated by MR lymphography due to reduced lymphatic flow or extravasated contrast medium at the abdominal puncture site.
Conclusion: Interstitial MR lymphography with Gadomer-17 allows sensitive detection and localization of abdominally located leaks of the thoracic duct.
Similar articles
-
[Interstitial T1-weighted MR lymphography with use of the dendritic contrast agent Gadomer-17 in pigs].Rofo. 2001 Dec;173(12):1131-6. doi: 10.1055/s-2001-18891. Rofo. 2001. PMID: 11740675 German.
-
[High-resolution T1-weighted MR-lymphography of inguinal lymph nodes after interstitial application of Gadomer-17 in animal experiments].Rofo. 2005 Jul;177(7):968-74. doi: 10.1055/s-2005-858239. Rofo. 2005. PMID: 15973599 German.
-
T1-weighted MR-lymphography after intramammary administration of Gadomer-17 in pigs.Rofo. 2002 Jan;174(1):29-32. doi: 10.1055/s-2002-19551. Rofo. 2002. PMID: 11793281
-
Modern Techniques of Lymphangiography and Interventions: Current Status and Future Development.Cardiovasc Intervent Radiol. 2018 Mar;41(3):366-376. doi: 10.1007/s00270-017-1863-2. Epub 2017 Dec 18. Cardiovasc Intervent Radiol. 2018. PMID: 29256071 Review.
-
Magnetic Resonance Lymphangiography.Radiol Clin North Am. 2020 Jul;58(4):693-706. doi: 10.1016/j.rcl.2020.02.002. Epub 2020 May 6. Radiol Clin North Am. 2020. PMID: 32471538 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical