Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
- PMID: 12585710
- DOI: 10.1109/TMI.2002.806283
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
Abstract
The quantitative analysis of magnetic resonance imaging (MRI) data has become increasingly important in both research and clinical studies aiming at human brain development, function, and pathology. Inevitably, the role of quantitative image analysis in the evaluation of drug therapy will increase, driven in part by requirements imposed by regulatory agencies. However, the prohibitive length of time involved and the significant intraand inter-rater variability of the measurements obtained from manual analysis of large MRI databases represent major obstacles to the wider application of quantitative MRI analysis. We have developed a fully automatic "pipeline" image analysis framework and have successfully applied it to a number of large-scale, multicenter studies (more than 1,000 MRI scans). This pipeline system is based on robust image processing algorithms, executed in a parallel, distributed fashion. This paper describes the application of this system to the automatic quantification of multiple sclerosis lesion load in MRI, in the context of a phase III clinical trial. The pipeline results were evaluated through an extensive validation study, revealing that the obtained lesion measurements are statistically indistinguishable from those obtained by trained human observers. Given that intra- and inter-rater measurement variability is eliminated by automatic analysis, this system enhances the ability to detect small treatment effects not readily detectable through conventional analysis techniques. While useful for clinical trial analysis in multiple sclerosis, this system holds widespread potential for applications in other neurological disorders, as well as for the study of neurobiology in general.
Similar articles
-
Multiple sclerosis medical image analysis and information management.J Neuroimaging. 2005;15(4 Suppl):103S-117S. doi: 10.1177/1051228405282864. J Neuroimaging. 2005. PMID: 16385023 Review.
-
Brain imaging in drug R&D.Biomarkers. 2005 Nov;10 Suppl 1:S58-68. doi: 10.1080/13547500500214392. Biomarkers. 2005. PMID: 16298913 Review.
-
Quantification of multiple sclerosis lesion load and brain tissue volumetry using multiparameter MRI: methodology and reproducibility.Magn Reson Imaging. 2005 Apr;23(3):445-52. doi: 10.1016/j.mri.2004.12.005. Magn Reson Imaging. 2005. PMID: 15862645
-
MRI texture analysis in multiple sclerosis: toward a clinical analysis protocol.Acad Radiol. 2010 Jun;17(6):696-707. doi: 10.1016/j.acra.2010.01.005. Acad Radiol. 2010. PMID: 20457414
-
Voxel-based iterative sensitivity (VBIS) analysis: methods and a validation of intensity scaling for T2-weighted imaging of hippocampal sclerosis.Neuroimage. 2009 Feb 1;44(3):812-9. doi: 10.1016/j.neuroimage.2008.09.055. Epub 2008 Oct 19. Neuroimage. 2009. PMID: 18996207
Cited by
-
DISC1 and Striatal Volume: A Potential Risk Phenotype For mental Illness.Front Psychiatry. 2012 Jun 19;3:57. doi: 10.3389/fpsyt.2012.00057. eCollection 2012. Front Psychiatry. 2012. PMID: 22723785 Free PMC article.
-
Anatomical substrates of the alerting, orienting and executive control components of attention: focus on the posterior parietal lobe.PLoS One. 2012;7(11):e50590. doi: 10.1371/journal.pone.0050590. Epub 2012 Nov 30. PLoS One. 2012. PMID: 23226322 Free PMC article.
-
Computer-Aided Detection and Diagnosis of Neurological Disorder.Cureus. 2022 Aug 15;14(8):e28032. doi: 10.7759/cureus.28032. eCollection 2022 Aug. Cureus. 2022. PMID: 36120284 Free PMC article. Review.
-
Verbal memory is associated with structural hippocampal changes in newly diagnosed Parkinson's disease.J Neurol Neurosurg Psychiatry. 2013 Jan;84(1):23-8. doi: 10.1136/jnnp-2012-303054. Epub 2012 Nov 15. J Neurol Neurosurg Psychiatry. 2013. PMID: 23154124 Free PMC article.
-
Smoking normalizes cerebral blood flow and oxygen consumption after 12-hour abstention.J Cereb Blood Flow Metab. 2015 Mar 31;35(4):699-705. doi: 10.1038/jcbfm.2014.246. J Cereb Blood Flow Metab. 2015. PMID: 25605288 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical