Feature-guided shape-based image interpolation
- PMID: 12588032
- DOI: 10.1109/TMI.2002.806574
Feature-guided shape-based image interpolation
Abstract
A feature-guided image interpolation scheme is presented. It is an effective and improved, shape-based interpolation method used for interpolating image slices in medical applications. The proposed method integrates feature line-segments to guide the shape-based method for better shape interpolation. An automatic method for finding these line segments is given. The proposed feature-guided shape-based method can manage translation, rotation and scaling situations when the slices have similar shapes. It can also interpolate intermediate shapes when the successive slices do not have similar shapes. This method is experimentally evaluated using artificial and real two-dimensional and three-dimensional data. The proposed method generated satisfactory interpolated results in these experiments. We demonstrate the practicality, effectiveness and reproducibility of the proposed method for interpolating medical images.
Similar articles
-
Optical flow based volumetric spatio-temporal interpolation.Annu Int Conf IEEE Eng Med Biol Soc. 2008;2008:3979-82. doi: 10.1109/IEMBS.2008.4650081. Annu Int Conf IEEE Eng Med Biol Soc. 2008. PMID: 19163584
-
A morphology-based approach for interslice interpolation of anatomical slices from volumetric images.IEEE Trans Biomed Eng. 2008 Aug;55(8):2022-38. doi: 10.1109/TBME.2008.921158. IEEE Trans Biomed Eng. 2008. PMID: 18632365
-
Interpolation of 3-D binary images based on morphological skeletonization.IEEE Trans Med Imaging. 2000 Jul;19(7):699-710. doi: 10.1109/42.875192. IEEE Trans Med Imaging. 2000. PMID: 11055785
-
Statistical shape models for 3D medical image segmentation: a review.Med Image Anal. 2009 Aug;13(4):543-63. doi: 10.1016/j.media.2009.05.004. Epub 2009 May 27. Med Image Anal. 2009. PMID: 19525140 Review.
-
Mutual-information-based registration of medical images: a survey.IEEE Trans Med Imaging. 2003 Aug;22(8):986-1004. doi: 10.1109/TMI.2003.815867. IEEE Trans Med Imaging. 2003. PMID: 12906253 Review.
Cited by
-
Inter-subject comparison of MRI knee cartilage thickness.Med Image Anal. 2008 Apr;12(2):120-35. doi: 10.1016/j.media.2007.08.002. Epub 2007 Aug 31. Med Image Anal. 2008. PMID: 17923429 Free PMC article.
-
Improved neonatal brain MRI segmentation by interpolation of motion corrupted slices.J Neuroimaging. 2022 May;32(3):480-492. doi: 10.1111/jon.12985. Epub 2022 Mar 7. J Neuroimaging. 2022. PMID: 35253956 Free PMC article.
-
A hybrid approach to shape-based interpolation of stereotactic atlases of the human brain.Neuroinformatics. 2006;4(2):177-98. doi: 10.1385/NI:4:2:177. Neuroinformatics. 2006. PMID: 16845168
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources