Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidneys using a 14-gauge Biopty gun
- PMID: 12594555
- DOI: 10.1007/s00330-002-1482-3
Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidneys using a 14-gauge Biopty gun
Abstract
Our objective was to evaluate the safety and diagnostic efficacy of the ultrasound-guided renal biopsy procedure using an automated biopsy device (Biopty gun) with a 14-gauge needle. Five hundred fifteen consecutive ultrasound-guided renal biopsies performed in two large university hospitals were retrospectively reviewed. Three hundred forty-five biopsies were performed on renal allografts and 170 on native kidneys. The tissue specimen was adequate for histological evaluation in 95.3% of the cases (94.8% in the transplanted kidney group, 96.5% in the native kidney group). The overall complication rate was 12.2% and was significantly higher in the native kidney group (19.4%) than in the renal allograft group (8.7%). Major complications occurred in 2.7% of the cases (2.9% of the renal allografts and 2.4% of the native kidney biopsies), including one procedure-related death and the loss of the renal allograft in two other patients. Minor complications were noted in 9.5% of the biopsies and there were significantly more in the group of the native kidneys (17.1%) than in the group of the transplanted kidneys (5.8%). Renal biopsy with an automated device using a 14-gauge needle has a high tissue recovery rate, but it is associated with a small risk of serious complications.
Similar articles
-
Safety and efficacy of kidney transplant biopsy: Tru-Cut needle vs sonographically guided Biopty gun.AJR Am J Roentgenol. 1993 Feb;160(2):325-6. doi: 10.2214/ajr.160.2.8424343. AJR Am J Roentgenol. 1993. PMID: 8424343
-
Renal biopsy in diffuse renal disease--experience with a 14-gauge automated biopsy gun.Clin Radiol. 1992 Aug;46(2):111-3. doi: 10.1016/s0009-9260(05)80314-9. Clin Radiol. 1992. PMID: 1395398
-
Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.Acta Radiol. 1997 May;38(3):431-6. doi: 10.1080/02841859709172096. Acta Radiol. 1997. PMID: 9191436
-
Outcomes of percutaneous kidney biopsy, including those of solitary native kidneys.Am J Kidney Dis. 1995 Oct;26(4):580-5. doi: 10.1016/0272-6386(95)90592-8. Am J Kidney Dis. 1995. PMID: 7573010 Review.
-
Complications of percutaneous renal biopsy.J Indian Med Assoc. 1994 Dec;92(12):395-6. J Indian Med Assoc. 1994. PMID: 7876577 Review.
Cited by
-
Nontargeted Native Renal Biopsy Adequacy: Preintervention Data From a Province-Wide, Multicentre, and Interdepartmental Audit.Can J Kidney Health Dis. 2023 Oct 14;10:20543581231205161. doi: 10.1177/20543581231205161. eCollection 2023. Can J Kidney Health Dis. 2023. PMID: 37841342 Free PMC article.
-
Non-invasive evaluation of stable renal allograft function using point shear-wave elastography.Br J Radiol. 2018 Jan;91(1081):20170372. doi: 10.1259/bjr.20170372. Epub 2017 Oct 31. Br J Radiol. 2018. PMID: 29022743 Free PMC article.
-
Percutaneous native renal biopsy adequacy: a successful interdepartmental quality improvement activity.Can J Kidney Health Dis. 2015 Mar 13;2:8. doi: 10.1186/s40697-015-0043-z. eCollection 2015. Can J Kidney Health Dis. 2015. PMID: 27408754 Free PMC article.
-
Systematic review of ablative therapy for the treatment of renal allograft neoplasms.World J Clin Cases. 2019 Sep 6;7(17):2487-2504. doi: 10.12998/wjcc.v7.i17.2487. World J Clin Cases. 2019. PMID: 31559284 Free PMC article.
-
Identification of a urine metabolite constellation characteristic for kidney allograft rejection.Metabolomics. 2018 Aug 30;14(9):116. doi: 10.1007/s11306-018-1419-8. Metabolomics. 2018. PMID: 30830387 Free PMC article.