A simple measure of flow disorder and wall shear stress in phase contrast MRI
- PMID: 12594758
- DOI: 10.1002/mrm.10409
A simple measure of flow disorder and wall shear stress in phase contrast MRI
Abstract
A method for estimating the standard deviation of velocity within a voxel is proposed. This estimate is based on data collected using a phase-contrast MRI technique. Simulations are presented to characterize the estimate and in vivo data are shown. Several different uses of the estimate are proposed, including obtaining a measure of wall shear stress, aiding in data combination from different phase-contrast MRI datasets, and mitigation of flow void artifacts.
Copyright 2003 Wiley-Liss, Inc.
Similar articles
-
Simulation of phase contrast MRI of turbulent flow.Magn Reson Med. 2010 Oct;64(4):1039-46. doi: 10.1002/mrm.22494. Magn Reson Med. 2010. PMID: 20574963
-
Assessment of the accuracy of MRI wall shear stress estimation using numerical simulations.J Magn Reson Imaging. 2012 Jul;36(1):128-38. doi: 10.1002/jmri.23610. Epub 2012 Feb 15. J Magn Reson Imaging. 2012. PMID: 22336966
-
Effects of intravoxel velocity distributions on the accuracy of the phase-mapping method in phase-contrast MR angiography.J Magn Reson Imaging. 1994 Sep-Oct;4(5):752-5. doi: 10.1002/jmri.1880040520. J Magn Reson Imaging. 1994. PMID: 7981522
-
The combination of magnetic resonance angiography and computational fluid dynamics: a critical review.Crit Rev Biomed Eng. 1998;26(4):227-74. doi: 10.1615/critrevbiomedeng.v26.i4.10. Crit Rev Biomed Eng. 1998. PMID: 10065891 Review.
-
Functional radiology of the liver: magnetic resonance imaging.Rays. 1997 Apr-Jun;22(2):295-312. Rays. 1997. PMID: 9351333 Review. English, Italian.
Cited by
-
A New Method for Quantifying Abdominal Aortic Wall Shear Stress Using Phase Contrast Magnetic Resonance Imaging and the Womersley Solution.J Biomech Eng. 2022 Sep 1;144(9):091011. doi: 10.1115/1.4054236. J Biomech Eng. 2022. PMID: 35377416 Free PMC article.
-
Application of flow sensitive gradients for improved measures of metabolism using hyperpolarized (13) c MRI.Magn Reson Med. 2016 Mar;75(3):1242-8. doi: 10.1002/mrm.25584. Epub 2015 May 6. Magn Reson Med. 2016. PMID: 25951611 Free PMC article.
-
Improved SNR in phase contrast velocimetry with five-point balanced flow encoding.Magn Reson Med. 2010 Feb;63(2):349-55. doi: 10.1002/mrm.22202. Magn Reson Med. 2010. PMID: 20099326 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources