Cardiac failure and upper extremity arteriovenous dialysis fistulas. Case reports and a review of the literature
- PMID: 1259499
Cardiac failure and upper extremity arteriovenous dialysis fistulas. Case reports and a review of the literature
Abstract
Nine patients with high-output cardiac failure from arteriovenous forearm dialysis fistulas are reviewed, and six new cases are presented. Decreases in cardiac output with temporary fistula occlusion ranged from 0.3 to 11.0 liters/min (mean, 2.9 liters/min); fistula flow rates varied from 0.6 to 2.9 liter/min (mean, 1.5 liters/min). Surgical correction of high-flow fistulas resulted in notable improvement of cardiac failure in 13 of 14 patients. Although cardiac failure in individuals who are receiving long-term dialysis treatment is usually caused by intrinsic cardiac disease, volume overload, or anemia, forearm fistulas with large flow rates may be an important contributing factor. Correction of these large flow rates may be an important contributing factor. Correction of these large flow rates by banding or closure can substantially improve cardiac function in selected patients.
Similar articles
-
High-output cardiac failure secondary to a brachiocephalic arteriovenous hemodialysis fistula: two cases.Am Surg. 1998 Mar;64(3):239-41. Am Surg. 1998. PMID: 9520814
-
Limb growth and cardiac complications of fistulas in children.Int J Pediatr Nephrol. 1987 Jul-Sep;8(3):167-70. Int J Pediatr Nephrol. 1987. PMID: 3429139
-
The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patients.Nephrol Dial Transplant. 2008 Jan;23(1):282-7. doi: 10.1093/ndt/gfm549. Epub 2007 Oct 17. Nephrol Dial Transplant. 2008. PMID: 17942475
-
High-output heart failure: how to define it, when to treat it, and how to treat it.Semin Nephrol. 2012 Nov;32(6):551-7. doi: 10.1016/j.semnephrol.2012.10.006. Semin Nephrol. 2012. PMID: 23217335 Review.
-
The cardiovascular effects of arteriovenous fistulas in chronic kidney disease: a cause for concern?Semin Dial. 2006 Sep-Oct;19(5):349-52. doi: 10.1111/j.1525-139X.2006.00185.x. Semin Dial. 2006. PMID: 16970729 Review.
Cited by
-
Association of Borderline Pulmonary Hypertension With Mortality and Hospitalization in a Large Patient Cohort: Insights From the Veterans Affairs Clinical Assessment, Reporting, and Tracking Program.Circulation. 2016 Mar 29;133(13):1240-8. doi: 10.1161/CIRCULATIONAHA.115.020207. Epub 2016 Feb 12. Circulation. 2016. PMID: 26873944 Free PMC article.
-
High output cardiac failure secondary to a Brescia-Cimino fistula.J Natl Med Assoc. 1979 Mar;71(3):285-7. J Natl Med Assoc. 1979. PMID: 439161 Free PMC article.
-
The deleterious effects of arteriovenous fistula-creation on the cardiovascular system: a longitudinal magnetic resonance imaging study.Int J Nephrol Renovasc Dis. 2014 Sep 16;7:337-45. doi: 10.2147/IJNRD.S66390. eCollection 2014. Int J Nephrol Renovasc Dis. 2014. PMID: 25258554 Free PMC article.
-
Graft Inclusion Technique: A New Flow Reduction Procedure for High Flow Arteriovenous Fistulae.Ann Vasc Dis. 2018 Jun 25;11(2):202-209. doi: 10.3400/avd.oa.17-00132. Ann Vasc Dis. 2018. PMID: 30116412 Free PMC article.
-
Controversies in the management of the haemodialysis-related arteriovenous fistula following kidney transplantation.Clin Kidney J. 2018 Jun;11(3):406-412. doi: 10.1093/ckj/sfx113. Epub 2017 Oct 18. Clin Kidney J. 2018. PMID: 29992020 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources