Monochromatic wavefront aberrations in the human eye with contact lenses
- PMID: 12597328
- DOI: 10.1097/00006324-200302000-00009
Monochromatic wavefront aberrations in the human eye with contact lenses
Abstract
Purpose: The aim of this study was to investigate the effect of contact lenses on the optical performance of the eye by measuring wavefront aberrations for the eyes with or without contact lenses.
Method: A sensitive aberrometer was used to measure wavefront aberrations for 54 eyes in 27 subjects for three conditions: with no contact lens (non-CL), with soft-contact lenses (soft-CL) and with rigid gas permeable contact lenses (RGP-CL). The root mean square (RMS) value of the wavefront aberrations and Zernike aberrations were calculated.
Results: A change in the RMS values of wavefront aberrations with CL wear was observed for every eye. The change in wavefront aberrations with CL wearing was found to vary substantially from individual to individual. Relative to the mean RMS value of the group for the non-CL condition, the mean RMS value was increased for the soft-CL condition and was significantly reduced for the RGP-CL condition. A significant increase in mean RMS for the soft-CL condition was found when astigmatisms were removed. Although soft-CL wearing resulted in significant increases in higher orders of Zernike aberrations (fourth, fifth, and higher), the RGP-CL condition led to a significant decrease in second-order Zernike aberrations. For the eyes with low wavefront aberrations in the non-CL condition, either soft-CL wearing or RGP-CL wearing results in increases in the RMS values.
Conclusion: Contact lens wearing, either with soft lenses or the RGP lenses, causes changes in the wavefront aberrations of the eye. The changes in wavefront aberrations vary substantially from eye to eye. Although soft-CL wearing tends to induce more higher-order aberrations, RGP-CL effectively reduces the astigmatisms. Both soft-CL and RGP-CL induce more aberrations for the eyes that have low wavefront aberrations. The change in wavefront aberrations due to contact lens wearing may explain the changes in visual performance for contact lens wearers reported previously.
Similar articles
-
A comparison of wavefront aberrations in eyes wearing different types of soft contact lenses.Optom Vis Sci. 2006 Oct;83(10):769-74. doi: 10.1097/01.opx.0000236786.96023.9c. Optom Vis Sci. 2006. PMID: 17041323 Clinical Trial.
-
On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry.Optom Vis Sci. 2003 Feb;80(2):115-25. doi: 10.1097/00006324-200302000-00007. Optom Vis Sci. 2003. PMID: 12597326
-
Optical quality and visual performance with customised soft contact lenses for keratoconus.Ophthalmic Physiol Opt. 2014 Sep;34(5):528-39. doi: 10.1111/opo.12133. Epub 2014 Apr 24. Ophthalmic Physiol Opt. 2014. PMID: 24758229
-
A European fitting philosophy for aspheric, high-Dk RGP contact lenses.CLAO J. 1992 Oct;18(4):232-6. CLAO J. 1992. PMID: 1424057 Review.
-
Astigmatic Peripheral Defocus with Different Contact Lenses: Review and Meta-Analysis.Curr Eye Res. 2016 Aug;41(8):1005-1015. doi: 10.3109/02713683.2015.1116585. Epub 2016 Feb 2. Curr Eye Res. 2016. PMID: 26835871 Review.
Cited by
-
Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses.Int J Ophthalmol. 2013 Apr 18;6(2):178-82. doi: 10.3980/j.issn.2222-3959.2013.02.14. Print 2013. Int J Ophthalmol. 2013. PMID: 23638420 Free PMC article.
-
Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses.J Curr Ophthalmol. 2016 Jul 25;28(4):226-227. doi: 10.1016/j.joco.2016.07.002. eCollection 2016 Dec. J Curr Ophthalmol. 2016. PMID: 27830209 Free PMC article.
-
Assessment of aberrations and visual quality differences between myopic and astigmatic eyes before and after contact lens application.North Clin Istanb. 2015 Apr 24;2(1):1-6. doi: 10.14744/nci.2015.87487. eCollection 2015. North Clin Istanb. 2015. PMID: 28058332 Free PMC article.
-
Does Long-term Soft Contact Lens Wear Affect Corneal and Anterior Chamber Parameters?Turk J Ophthalmol. 2018 Aug;48(4):166-170. doi: 10.4274/tjo.53486. Epub 2018 Sep 4. Turk J Ophthalmol. 2018. PMID: 30202611 Free PMC article.
-
Spherical aberration and higher order aberrations with Balafilcon A (PureVision) and Comfilcon A (Biofinity).Graefes Arch Clin Exp Ophthalmol. 2011 Apr;249(4):607-12. doi: 10.1007/s00417-010-1476-9. Epub 2010 Aug 6. Graefes Arch Clin Exp Ophthalmol. 2011. PMID: 20694473 Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical