Use of high concentration contrast media: principles and rationale-vascular district
- PMID: 12598032
- DOI: 10.1016/s0720-048x(02)00365-0
Use of high concentration contrast media: principles and rationale-vascular district
Abstract
Optimal contrast medium delivery remains a crucial issue in CT angiography and it will become even more critical with continuously evolving, faster CT scanner technology. This review article first explains the fundamentals of arterial enhancement using mathematical models of early contrast medium dynamics. The relationship of contrast medium volume, injection flow rates and injection duration are explicitly illustrated. Next, current techniques of contrast medium application are reviewed, with particular attention to methods of accurate timing of the scanning delay (test-bolus and automated bolus triggering), tools for automated saline-flushing of the veins (double-syringe power injectors) and the use of high-concentration contrast medium. From there, rational CT angiographic injection protocols for a wide range of selectable acquisition times for 4-, 8- and 16-channel MDCT are proposed.
Similar articles
-
Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale.Eur Radiol. 2003 Dec;13 Suppl 5:M14-20. doi: 10.1007/s00330-003-2097-z. Eur Radiol. 2003. PMID: 14989606 Review.
-
CT angiography: injection and acquisition technique.Radiol Clin North Am. 2010 Mar;48(2):237-47, vii. doi: 10.1016/j.rcl.2010.02.002. Radiol Clin North Am. 2010. PMID: 20609872 Review.
-
How to design injection protocols for multiple detector-row CT angiography (MDCTA).Eur Radiol. 2005 Dec;15 Suppl 5:E60-5. doi: 10.1007/s10406-005-0166-x. Eur Radiol. 2005. PMID: 18637231 Review.
-
Optimal vascular and parenchymal contrast enhancement: the current state of the art.Radiol Clin North Am. 2009 Jan;47(1):13-26. doi: 10.1016/j.rcl.2008.10.009. Radiol Clin North Am. 2009. PMID: 19195531 Review.
-
[Feasibility and optimization of the combined injection of contrast medium and normal saline with a single-syringe CT injection system].Rofo. 2003 Jun;175(6):844-8. doi: 10.1055/s-2003-39922. Rofo. 2003. PMID: 12811699 German.
Cited by
-
Test bolus measurement: effects of the respiratory position on bolus arrival time and signal-intensity-time curve quality.MAGMA. 2007 Oct;20(4):175-9. doi: 10.1007/s10334-007-0080-4. Epub 2007 Sep 5. MAGMA. 2007. PMID: 17786494
-
Which Iodine concentration in chest CT?--a prospective study in 300 patients.Eur Radiol. 2008 Dec;18(12):2826-32. doi: 10.1007/s00330-008-1080-0. Epub 2008 Jul 24. Eur Radiol. 2008. PMID: 18651154
-
Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial.Korean J Radiol. 2016 May-Jun;17(3):330-8. doi: 10.3348/kjr.2016.17.3.330. Epub 2016 Apr 14. Korean J Radiol. 2016. PMID: 27134522 Free PMC article. Clinical Trial.
-
Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography.PLoS One. 2015 Jul 13;10(7):e0132412. doi: 10.1371/journal.pone.0132412. eCollection 2015. PLoS One. 2015. PMID: 26167680 Free PMC article. Clinical Trial.
-
Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA.Eur Radiol. 2006 Jan;16(1):137-46. doi: 10.1007/s00330-005-2812-z. Epub 2005 Jun 30. Eur Radiol. 2006. PMID: 15988586 Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources