Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Apr;36(4):505-12.
doi: 10.1016/s0021-9290(02)00430-x.

Correlation between active and passive isometric force and intramuscular pressure in the isolated rabbit tibialis anterior muscle

Affiliations

Correlation between active and passive isometric force and intramuscular pressure in the isolated rabbit tibialis anterior muscle

Jennifer Davis et al. J Biomech. 2003 Apr.

Abstract

The purpose of this study was to quantify the relationship between intramuscular pressure (IMP) and muscle force during isometric muscle contraction of the rabbit tibialis anterior (TA) absent the effect of either bone or fascia. To quantify this relationship, length-tension experiments were performed on the isolated TA of the New Zealand White rabbit (mass=2.5+/-0.5kg, n=12). The knee was fixed in a custom jig, the distal tendon of the TA was attached to a servomotor, and a 360 microm fiber optic pressure transducer was inserted into the TA. The peroneal nerve was stimulated to define optimal length (L(0)). The length-tension curve was created using 40Hz isometric contractions with 2-min rest intervals between each contraction. Measurements began at L(0)-50%L(f) and progressed to L(0)+50%L(f), changing the length-tension in 5% L(f) increments after each contraction. Qualitatively, the length-tension curve for isometric contractions was mimicked by the length-pressure curve for both active and passive conditions. Linear regression was performed individually for each animal for the ascending and descending limb of the length-tension curve and for active and passive conditions. Pressure-force coefficients of determination ranged from 0.138-0.963 for the active ascending limb and 0.343-0.947 for the active descending limb. Passive pressure coefficients of determination ranged from 0.045-0.842 for the ascending limb and 0.672-0.982 for the descending limb. These data indicate that IMP measurement provide a fairly accurate index of relative muscle force, especially at muscle lengths longer than optimal.

PubMed Disclaimer

Publication types

LinkOut - more resources