Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Mar;44(3):1070-4.
doi: 10.1167/iovs.02-0343.

Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure

Affiliations
Comparative Study

Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure

Jianhua Wang et al. Invest Ophthalmol Vis Sci. 2003 Mar.

Abstract

Purpose: To determine changes in topographical thickness of the epithelium and total cornea after hydrogel (2-hydroxyethyl methacrylate; HEMA or soft lens) and PMMA rigid contact lens wear with eyes closed, as measured by optical coherence tomography (OCT).

Methods: Epithelial and total corneal thickness in 18 neophyte eyes was measured with OCT at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after 3 hours of soft and rigid contact lens wear with the eye closed. These measurements were repeated 20 minutes after removal of the lenses.

Results: Lens type, time, and location were found to be significant main influences (P < 0.0001) on corneal swelling in patched eyes, by three-way ANOVA, and there was a significant three-way interaction among lens type, time, and location (F((16,272)) = 1.78, P = 0.033). However, there was no significant main effect and interaction of epithelial thickness (F((16, 272)) = 0.33, P = 0.99). Immediately after removal of the lenses, total corneal thickness in the horizontal meridian was significantly greater with both soft and PMMA lenses (P < 0.001) at each location with each lens, compared with the baseline measurements. With both lenses, the increase in actual thickness and percentage of corneal swelling at the center was greater than at each peripheral point (excluding the first 10 degrees points; P < 0.005). HEMA lenses caused greater corneal swelling than the PMMA lenses at each location immediately after removal of the lenses (P < 0.005).

Conclusions: This study shows that corneal swelling is dependent on lens type and corneal location when eyes are closed, but epithelial thickness across the horizontal corneal meridian does not change during lens wear with eyes closed. OCT is an efficient method of measuring topographical corneal and epithelial thickness in response to contact lens wear.

PubMed Disclaimer

Publication types

LinkOut - more resources