. 2003 Jul 1;168(1):54-62.
doi: 10.1164/rccm.200211-1329OC. Epub 2003 Feb 25.

Persistent hyperreactivity and reactive airway dysfunction in firefighters at the World Trade Center

Affiliations

Persistent hyperreactivity and reactive airway dysfunction in firefighters at the World Trade Center

Gisela I Banauch et al. Am J Respir Crit Care Med. .

Abstract

New York City Fire Department rescue workers experienced massive exposure to airborne particulates at the World Trade Center site. Aims of this longitudinal study were to (1) determine if bronchial hyperreactivity was present, persistent, and independently associated with exposure intensity, (2) identify objective measures shortly after the collapse that would predict persistent hyperreactivity and a diagnosis of reactive airways dysfunction 6 months post-collapse. A representative sample of 179 rescue workers stratified by exposure intensity (high, moderate, and control) without current smoking or prior respiratory disease was enrolled. Highly exposed workers arrived within 2 hours of collapse, moderately exposed workers arrived later on Days 1-2; control subjects were not exposed. Hyperreactivity at 1, 3, and 6 months post-collapse was associated with exposure intensity, independent of ex-smoking and airflow obstruction. Six months post-collapse, highly exposed workers were 6.8 times more likely than moderately exposed workers and control subjects to be hyperreactive (95% confidence interval, 1.8-25.2; p = 0.004), and hyperreactivity persisted in 55% of those hyperreactive at 1 and/or 3 months. In highly exposed subjects, hyperreactivity 1 or 3 months post-collapse was the sole predictor for reactive airways dysfunction (p = 0.021). In conclusion, development and persistence of hyperreactivity and reactive airways dysfunction were strongly and independently associated with exposure intensity. Hyperreactivity shortly post-collapse predicted reactive airways dysfunction at 6 months in highly exposed workers; this has important implications for disaster management.

PubMed Disclaimer

Comment in

  • Reactive fallout of World Trade Center dust.
    Nemery B. Nemery B. Am J Respir Crit Care Med. 2003 Jul 1;168(1):2-3. doi: 10.1164/rccm.2304005. Am J Respir Crit Care Med. 2003. PMID: 12826591 Review. No abstract available.
  • World Trade Center dust and airway reactivity.
    Truncale T, Brooks S, Prezant DJ, Banauch GI, Nemery B. Truncale T, et al. Am J Respir Crit Care Med. 2004 Apr 1;169(7):883-4; author reply 884-5. doi: 10.1164/ajrccm.169.7.954. Am J Respir Crit Care Med. 2004. PMID: 15044224 No abstract available.

Publication types

MeSH terms