Clinical Trial
. 2003 Feb;28(1):9-12.
doi: 10.1016/S1473-0502(02)00094-0.

Malpositioning of Hickman catheters, left versus right sided attempts

Affiliations
Clinical Trial

Malpositioning of Hickman catheters, left versus right sided attempts

Ali Ekrem Unal et al. Transfus Apher Sci. 2003 Feb.

Abstract

Background: Central venous catheters (CVC) are frequently used for stem cell collection and recurrent therapeutic hemapheresis procedures for patients with poor peripheral venous access. There is a tendency to prefer a right sided approach for insertion of a CVC via the subclavian route. We designed a sequential randomized study to examine the issue of catheter insertion side and analyzed all the technical data on surgical skill and observed complications.

Method: Seventy-five patients who are candidates for stem cell collection and high dose chemotherapy underwent placement of Hickman catheters via the percutaneous subclavian vein (SCV) route. One experienced surgeon inserted 12F, double lumen, tunnelled, silicon based catheters in the operation room via fluoroscopic control. All of the procedure related complications, morbidity and mortality were analyzed on the basis of the side of catheter insertion.

Results: The total rate of malpositioning in this series was 14.66%. The Jugular vein was the most common malpositioning site (66.6%). We observed a statistically significant difference in malpositioning between left versus right sided attempts, at 5.55% versus 20.51%, respectively (p = 0.032). The routes of malpositioning encountered for left sided attempts were the right SCV and the left internal jugular vein, the right internal jugular vein (n = 5), the left SCV vein (n = 2), and one left internal jugular vein. There was no significant difference between the right and left sided attempts for mechanical complications other than malpositioning (p < 0.05).

Conclusion: In this study the rate of malpositioning was greater in the right sided approach (p = 0.032) and the other mechanical complication rates did not differ for the two methods. Our results indicate that there is no need for hesitancy in using left sided attempts at CVC insertion.