High-throughput cytochrome p450 inhibition assays by ultrafast gradient liquid chromatography with tandem mass spectrometry using monolithic columns
- PMID: 12621611
- DOI: 10.1002/rcm.941
High-throughput cytochrome p450 inhibition assays by ultrafast gradient liquid chromatography with tandem mass spectrometry using monolithic columns
Abstract
A generic method employing ultrafast liquid chromatography with tandem mass spectrometry (LC/MS/MS) was developed and employed for routine screening of drug candidates for inhibition of five major human cytochrome p450 (CYP) isozymes, CYP3A4, CYP2D6, CYP2C9, CYP2C19, and CYP1A2. The method utilized a monolithic silica rod column to allow fast flow rates to significantly reduce chromatographic run time. The major metabolites of six CYP-specific probe substrates for the five p450 isoforms were monitored and quantified to determine IC(50) values of five drug compounds against each p450 isozyme. Human liver microsomal incubation samples at each test compound concentration were combined and analyzed simultaneously by the LC/MS/MS method. Each pooled sample containing six substrates and an internal standard was separated and detected in only 24 seconds. The combination of ultrafast chromatography and sample pooling techniques has significantly increased sample throughput and shortened assay turnaround time, allowing a large number of compounds to be screened rapidly for potential p450 inhibitory activity, to aid in compound selection and optimization in drug discovery.
Copyright 2003 John Wiley & Sons, Ltd.
Similar articles
-
Use of stable isotope labeled probes to facilitate liquid chromatography/mass spectrometry based high-throughput screening of time-dependent CYP inhibitors.Rapid Commun Mass Spectrom. 2010 Aug 15;24(15):2177-85. doi: 10.1002/rcm.4610. Rapid Commun Mass Spectrom. 2010. PMID: 20583325
-
Validated method for rapid inhibition screening of six cytochrome P450 enzymes by liquid chromatography-tandem mass spectrometry.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Jun 1;852(1-2):128-37. doi: 10.1016/j.jchromb.2007.01.006. Epub 2007 Jan 13. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17267297
-
High-throughput, 384-well, LC-MS/MS CYP inhibition assay using automation, cassette-analysis technique, and streamlined data analysis.Drug Metab Lett. 2011 Aug;5(3):220-30. Drug Metab Lett. 2011. PMID: 21867481
-
Recent development in high-throughput bioanalytical support for in vitro ADMET profiling.Expert Opin Drug Metab Toxicol. 2010 Mar;6(3):321-36. doi: 10.1517/17425250903547829. Expert Opin Drug Metab Toxicol. 2010. PMID: 20163321 Review.
-
A review of LC-MS techniques and high-throughput approaches used to investigate drug metabolism by cytochrome P450s.J Chromatogr B Analyt Technol Biomed Life Sci. 2010 May 15;878(17-18):1326-36. doi: 10.1016/j.jchromb.2010.02.013. Epub 2010 Feb 17. J Chromatogr B Analyt Technol Biomed Life Sci. 2010. PMID: 20207203 Review.
Cited by
-
Quantitation of lanosterol and its major metabolite FF-MAS in an inhibition assay of CYP51 by azoles with atmospheric pressure photoionization based LC-MS/MS.J Am Soc Mass Spectrom. 2004 Aug;15(8):1216-21. doi: 10.1016/j.jasms.2004.04.036. J Am Soc Mass Spectrom. 2004. PMID: 15276168
-
Baihe Zhimu formula attenuates the efficacy of tamoxifen against breast cancer in mice through modulation of CYP450 enzymes.BMC Complement Altern Med. 2019 Sep 4;19(1):240. doi: 10.1186/s12906-019-2651-0. BMC Complement Altern Med. 2019. PMID: 31484532 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources