Design and performance characteristics of a whole-body positron transaxial tomograph
- PMID: 1262967
Design and performance characteristics of a whole-body positron transaxial tomograph
Abstract
A whole-body positron-emission transaxial tomograph (PETT III) is described in detail and evaluated in terms of resolution, accuracy, and efficiency. The PETT III utilizes annihilation coincidence detection to provide spatial resolution; high sensitivity is achieved by using 48 Nal(tl) detectors set in a hexagonal array with a multiple-coincidence logic. The assumptions and approximations made in the reconstruction and their effect on image quality are discussed. Phantom studies shows the depth-independent resolution and response of PETT III, as well as its ability to recover activity distribution quantitatively in the cross section measured. Images obtained with patients and normal volunteers show the potential clinical utility of PETT III.
Similar articles
-
Application of annihilation coincidence detection to transaxial reconstruction tomography.J Nucl Med. 1975 Mar;16(3):210-24. J Nucl Med. 1975. PMID: 1113170
-
A positron-emission transaxial tomograph for nuclear imaging (PETT).Radiology. 1975 Jan;114(1):89-98. doi: 10.1148/114.1.89. Radiology. 1975. PMID: 1208874
-
Determination of radionuclide concentrations with positron CT scanning (PETT): concise communication.J Nucl Med. 1977 Aug;18(8):845-7. J Nucl Med. 1977. PMID: 874174
-
Image quality with non-standard nuclides in PET.Q J Nucl Med Mol Imaging. 2008 Jun;52(2):151-8. Epub 2007 Nov 28. Q J Nucl Med Mol Imaging. 2008. PMID: 18043539 Review.
-
Whole-body magnetic resonance imaging and positron emission tomography-computed tomography in oncology.Top Magn Reson Imaging. 2007 Jun;18(3):193-202. doi: 10.1097/RMR.0b013e318093e6bo. Top Magn Reson Imaging. 2007. PMID: 17762383 Review.
Cited by
-
History and future technical innovation in positron emission tomography.J Med Imaging (Bellingham). 2017 Jan;4(1):011013. doi: 10.1117/1.JMI.4.1.011013. Epub 2017 Mar 31. J Med Imaging (Bellingham). 2017. PMID: 28401173 Free PMC article. Review.
-
Coupling between neuronal activity and microcirculation: implications for functional brain imaging.HFSP J. 2008 Apr;2(2):79-98. doi: 10.2976/1.2889618. Epub 2008 Mar 18. HFSP J. 2008. PMID: 19404475 Free PMC article.
-
Implementation of a Spatially-Variant and Tissue-Dependent Positron Range Correction for PET/CT Imaging.Front Physiol. 2022 Mar 8;13:818463. doi: 10.3389/fphys.2022.818463. eCollection 2022. Front Physiol. 2022. PMID: 35350691 Free PMC article.
-
Third Gordon Hamilton-Fairley Memorial Lecture. Tumour markers--where do we go from here?Br J Cancer. 1983 Aug;48(2):167-75. doi: 10.1038/bjc.1983.172. Br J Cancer. 1983. PMID: 6192836 Free PMC article.
-
Resolution Enhancement in PET Reconstruction Using Collimation.IEEE Trans Nucl Sci. 2013 Feb;60(1):65-75. doi: 10.1109/tns.2012.2214444. IEEE Trans Nucl Sci. 2013. PMID: 23493920 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources