Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Mar;61(3):518-22; discussion 522.
doi: 10.1016/s0090-4295(02)02433-0.

Assessment of stricture formation with the ureteral access sheath

Affiliations

Assessment of stricture formation with the ureteral access sheath

Fernando C Delvecchio et al. Urology. 2003 Mar.

Abstract

Objectives: To analyze the long-term incidence of ureteral stricture formation in a series of patients in whom a new-generation ureteral access sheath was used. A new generation of ureteral access sheaths has been developed to facilitate ureteroscopic procedures. However, some have questioned their safety and whether the device might cause significant ureteral trauma.

Methods: Between September 1999 and July 2001, 150 consecutive ureteroscopic procedures with adjunctive use of an access sheath were performed. A retrospective chart review to April 2002 was done. Of the 150 patients, 130 underwent ureteroscopy for ureteral stones. Patients who underwent endoureterotomy or treatment of transitional cell carcinoma were excluded from this analysis. Sixty-two patients had follow-up greater than 3 months and were included in the analysis. Overall, 71 ureteroscopic procedures were performed, with 9 patients undergoing multiple procedures. Ninety-two percent of the patients had pathologic findings above the iliac vessels. The average patient age was 45.3 years (range 17 to 76), and 70% and 30% of the patients were male and female, respectively. The mean clinical follow-up was 332 days (range 95 to 821), and follow-up imaging was performed within 3 months after ureteroscopy in all patients.

Results: The 10/12F access sheath was used in 8 ureteroscopic procedures (11.2%), the 12/14F access sheath in 56 (78.9%), and the 14/16F access sheath in 7 (9.8%). One stricture was identified on follow-up imaging of 71 procedures performed, for an incidence of 1.4%. The patient developed the stricture at the ureteropelvic junction after multiple ureteroscopic procedures to manage recurrent struvite calculi. The access sheath did not appear to be a contributing factor.

Conclusions: The results of our series indicate that the ureteral access sheath is safe and beneficial for routine use to facilitate flexible ureteroscopy. However, awareness of the potential ischemic effects with the use of unnecessarily large sheaths for long periods in patients at risk of ischemic injury should be considered. We advocate the routine use of the device for most flexible ureteroscopic procedures proximal to the iliac vessels.

PubMed Disclaimer

MeSH terms