Effect of off-pump coronary artery bypass grafting on risk-adjusted and cumulative sum failure outcomes after coronary artery surgery
- PMID: 12643463
- DOI: 10.1046/j.1540-8191.2002.01008.x
Effect of off-pump coronary artery bypass grafting on risk-adjusted and cumulative sum failure outcomes after coronary artery surgery
Abstract
Background and aim: We have shown that cumulative sum (CUSUM) failure analysis may be more sensitive than standard statistical methods in detecting a cluster of adverse patient outcomes after cardiac surgical procedures. We therefore applied CUSUM, as well as standard statistical techniques, to analyze a surgeon's experience with off-pump coronary artery bypass grafting (OPCAB) and on-pump procedures to determine whether the two techniques have similar or different outcomes.
Methods: In 320 patients undergoing nonemergent, first time coronary artery bypass grafting, preoperative patient characteristics, rates of mortality and major complications, and ICU and hospital lengths of stay were compared between the on-pump and OPCAB cohorts using Fisher's exact tests and Wilcoxon two sample tests. Predicted mortality and length of stay were determined using previously validated models of the Cardiac Care Network of Ontario. Observed versus expected ratios of both variables were calculated for the two types of procedures. Furthermore, CUSUM curves were constructed for the on-pump and OPCAB cohorts. A multivariable analysis of the predictors of hospital length of stay was also performed to determine whether the type of coronary artery bypass procedure had an independent impact on this variable.
Results: The predicted mortality risk and predicted hospital length of stay were almost identical in the 208 on-pump patients (2.2 +/- 3.9%; 8.2 +/- 2.5 days) and the 112 OPCAB patients (2.0 +/- 2.2%; 7.8 +/- 2.1 days). The incidence of hospital mortality and postoperative stroke were 2.9% and 2.4% in on-pump patients versus zero in OPCAB patients (p = 0.09 and 0.17, respectively). Mechanical ventilation for greater than 48 hours was significantly less common in OPCAB (1.8%) than in on-pump patients (7.7%, p = 0.04). The rate of 10 major complications was 14.9% in on-pump versus 8.0% in OPCAB patients (p = 0.08). OPCAB patients experienced a hospital length of stay that was a median of 1.0 day shorter than on-pump patients (p = 0.01). The observed versus expected ratio for length of stay was 0.78 in OPCAB patients versus 0.95 in on-pump patients. On CUSUM analysis, the failure curve in OPCAB patients was negative and was flatter than that of on-pump patients throughout the duration of the study. Furthermore, OPCAB was an independent predictor of a reduced hospital length of stay on multivariable analysis.
Conclusions: OPCAB was associated with better outcomes than on-pump coronary artery bypass despite a similar predicted risk. This robust finding was documented on sensitive CUSUM analysis, using standard statistical techniques and on a multivariable analysis of the independent predictors of hospital length of stay.
Similar articles
-
Cumulative sum failure analysis of a policy change from on-pump to off-pump coronary artery bypass grafting.Ann Thorac Surg. 2001 Sep;72(3):S1016-21. doi: 10.1016/s0003-4975(01)02949-6. Ann Thorac Surg. 2001. PMID: 11565718
-
In-hospital outcomes of off-pump versus on-pump coronary artery bypass procedures: a multicenter experience.Ann Thorac Surg. 2001 Nov;72(5):1528-33; discussion 1533-4. doi: 10.1016/s0003-4975(01)03202-7. Ann Thorac Surg. 2001. PMID: 11722038
-
Early outcomes of coronary artery bypass with and without cardiopulmonary bypass in octogenarians.Can J Cardiol. 2006 Aug;22(10):849-53. doi: 10.1016/s0828-282x(06)70303-8. Can J Cardiol. 2006. PMID: 16957802 Free PMC article.
-
Off-pump coronary artery bypass grafting improves short-term outcomes in high-risk patients compared with on-pump coronary artery bypass grafting: Meta-analysis.J Thorac Cardiovasc Surg. 2016 Jan;151(1):60-77.e1-58. doi: 10.1016/j.jtcvs.2015.08.042. Epub 2015 Aug 15. J Thorac Cardiovasc Surg. 2016. PMID: 26433633 Review.
-
Impact of off-pump to on-pump conversion rate on post-operative results in patients undergoing off-pump coronary artery bypass.Interact Cardiovasc Thorac Surg. 2012 Feb;14(2):188-93. doi: 10.1093/icvts/ivr071. Epub 2011 Nov 28. Interact Cardiovasc Thorac Surg. 2012. PMID: 22159253 Free PMC article. Review.
Cited by
-
Learning curves and surgical outcomes for proctored adoption of laparoscopic ventral mesh rectopexy: cumulative sum curve analysis.Surg Endosc. 2017 Mar;31(3):1421-1426. doi: 10.1007/s00464-016-5132-2. Epub 2016 Aug 5. Surg Endosc. 2017. PMID: 27495333
-
Intraoperative conversion to on-pump coronary artery bypass grafting is independently associated with higher mortality in patients undergoing off-pump coronary artery bypass grafting: A propensity-matched analysis.Ann Card Anaesth. 2016 Jul-Sep;19(3):475-80. doi: 10.4103/0971-9784.185534. Ann Card Anaesth. 2016. PMID: 27397452 Free PMC article.
-
Quality control of surgical and interventional procedures: a review of the CUSUM.Qual Saf Health Care. 2007 Jun;16(3):203-7. doi: 10.1136/qshc.2006.020776. Qual Saf Health Care. 2007. PMID: 17545347 Free PMC article. Review.
-
Off pump coronary artery bypass surgery in a Nigerian teaching hospital.Pan Afr Med J. 2013 Mar 28;14:122. doi: 10.11604/pamj.2013.14.122.2255. Print 2013. Pan Afr Med J. 2013. PMID: 23734267 Free PMC article.
-
Mid-term outcomes of off-pump versus on-pump coronary artery bypass graft surgery.Can J Cardiol. 2008 Apr;24(4):279-84. doi: 10.1016/s0828-282x(08)70177-6. Can J Cardiol. 2008. PMID: 18401468 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical