Clinical Trial
. 2003 Apr;96(4):1056-1061.
doi: 10.1213/01.ANE.0000050558.89090.95.

The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia

Affiliations
Clinical Trial

The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia

Augusto Tempia et al. Anesth Analg. 2003 Apr.

Abstract

The Anesthetic Conserving Device (ACD) is a high-flow anesthesia system closed to volatile anesthetics only. We compared the ACD with a circle system under different fresh gas flow (FGF) conditions. Eighty-one patients undergoing major surgery were randomly allocated to receive sevoflurane from a circle circuit combined either with the ACD placed at the Y-piece (n = 41) or with a vaporizer (n = 40). The FGF was set to 8 L/min in the ACD system, where the circle circuit served as a nonrebreather. In the conventional circle system without ACD, the vaporizer was supplied with 1-, 1.5-, 3-, and 6-L/min FGFs. We compared the ACD with the circle system under the four FGFs in terms of sevoflurane dosing, sevoflurane consumption, humidification efficiency, and environmental pollution. The ACD and the low-flow circle system (1.5- and 1-L/min FGFs) resulted in the smallest sevoflurane consumption. The increase in inspired sevoflurane concentration was faster with the circle system than with the ACD only with FGFs > or =3 L/min. The removal of ACD from the circuit allowed the fastest washout of sevoflurane. Respiratory gas humidification was always adequate. Sevoflurane ambient concentration with the ACD was 1-70 ppb. The ACD is a valid and simple alternative to low-flow systems.

Implications: The Anesthetic Conserving Device (ACD) is a new device for anesthetic vapor delivery. We demonstrated that the ACD reduces anesthetic consumption and environmental pollution similarly to a low-flow circle system, offering advantages such as simplicity, no toxicity from compounds produced in the absorber, and potential cost savings.

PubMed Disclaimer

References

    1. Baum JA, Aitkenhead AR. Low-flow anesthesia. Anaesthesia 1995; 50S: 37–44.
    1. Gowrie-Mohan S, Chakrabarti MK, Lockwood GG. The estimation of inspired isoflurane concentration in a low-flow system. Anaesthesia 1995; 50: 706–8.
    1. Gowrie-Mohan S, Muralitharan V, Lockwood GG. The estimation of inspired desflurane concentration in a low-flow system. Anaesthesia 1996; 51: 904–7.
    1. Frink EJ, Malan TP, Morgan SE, et al. Quantification of the degradation products of sevoflurane in two CO2 absorbants during low-flow anesthesia in surgical patients. Anesthesiology 1992; 77: 1064–9.
    1. Fang ZX, Eger EI II, Laster MJ, et al. Carbon monoxide production of degradation of desflurane, enflurane, isoflurane, halothane and sevoflurane by soda lime and Baralyme. Anesth Analg 1995; 80: 1187-93.

LinkOut - more resources