ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy
- PMID: 12657152
- DOI: 10.1046/j.1365-2591.2003.00628.x
ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy
Abstract
Aim: To investigate physical parameters for ProTaper nickel-titanium (NiTi) rotary instruments whilst preparing curved canals in maxillary molars in vitro.
Methodology: A novel torque-testing platform was used to prepare root canals in 15 extracted human maxillary molars with ProTaper rotary instruments. Peak torque and force was registered along with numbers of rotations required to shape the canals. Canals were divided into 'wide' and 'constricted' groups depending on canal volumes assessed by micro computed tomography. Mean scores for each instrument type were calculated and statistically compared using anova and Scheffé posthoc tests.
Results: Mean torque varied between 0.8 +/- 0.5 and 2.2 +/- 1.4 N cm whilst mean force ranged from 4.6 +/- 2.6 to 6.2 +/- 2.7 N. Mean numbers of rotations totalled up to 21. All three variables registered were significantly correlated to preoperative canal volumes (P < 0.001) and differed significantly between 'wide' and 'constricted' canals (P < 0.001).
Conclusions: Whilst high forces were used in some cases, no ProTaper instrument fractured when a patent glide path was present. There were significant positive correlations between canal geometry and physical parameters during shaping.
Similar articles
-
Root canal preparation with FlexMaster: asessment of torque and force in relation to canal anatomy.Int Endod J. 2003 Dec;36(12):883-90. doi: 10.1111/j.1365-2591.2003.00742.x. Int Endod J. 2003. PMID: 14641429
-
ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CT.Int Endod J. 2003 Feb;36(2):86-92. doi: 10.1046/j.1365-2591.2003.00626.x. Int Endod J. 2003. PMID: 12657151
-
Root-canal preparation with FlexMaster: canal shapes analysed by micro-computed tomography.Int Endod J. 2003 Nov;36(11):740-7. doi: 10.1046/j.1365-2591.2003.00723.x. Int Endod J. 2003. PMID: 14641437
-
Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient.J Endod. 2003 Sep;29(9):567-75. doi: 10.1097/00004770-200309000-00007. J Endod. 2003. PMID: 14503829
-
Torque Generation of the Endodontic Instruments: A Narrative Review.Materials (Basel). 2022 Jan 17;15(2):664. doi: 10.3390/ma15020664. Materials (Basel). 2022. PMID: 35057383 Free PMC article. Review.
Cited by
-
The influence of the irrigant QMix on the push-out bond strength of a bioceramic endodontic sealer.Eur Oral Res. 2018 May;52(2):64-68. doi: 10.26650/eor.2018.446. Epub 2018 May 1. Eur Oral Res. 2018. PMID: 30775704 Free PMC article.
-
Microscopic Features of Fractured Fragment of Nickel-Titanium Endodontic Instruments by Two Different Modes of Torsional Loading.Scanning. 2018 Feb 21;2018:9467059. doi: 10.1155/2018/9467059. eCollection 2018. Scanning. 2018. PMID: 29675119 Free PMC article.
-
Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.Odontology. 2016 May;104(2):192-8. doi: 10.1007/s10266-015-0199-0. Epub 2015 Feb 21. Odontology. 2016. PMID: 25701538
-
Comparative Evaluation of Surface Roughness of Different Rotary Nickel-Titanium (NiTi) Files After Autoclaving: An Atomic Force Microscopic Study.Cureus. 2024 Aug 3;16(8):e66054. doi: 10.7759/cureus.66054. eCollection 2024 Aug. Cureus. 2024. PMID: 39224719 Free PMC article.
-
Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.J Conserv Dent. 2011 Jul;14(3):282-6. doi: 10.4103/0972-0707.85817. J Conserv Dent. 2011. PMID: 22025834 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources