A novel design method of ratiometric fluorescent probes based on fluorescence resonance energy transfer switching by spectral overlap integral
- PMID: 12658644
- DOI: 10.1002/chem.200390167
A novel design method of ratiometric fluorescent probes based on fluorescence resonance energy transfer switching by spectral overlap integral
Abstract
A ratiometric measurement, namely, simultaneous recording of the fluorescence intensities at two wavelengths and calculation of their ratio, allows greater precision than measurements at a single wavelength, and is suitable for cellular imaging studies. Here we describe a novel method of designing probes for ratiometric measurement of hydrolytic enzyme activity based on switching of fluorescence resonance energy transfer (FRET). This method employs fluorescent probes with a 3'-O,6'-O-protected fluorescein acceptor linked to a coumarin donor through a linker moiety. As there is no spectral overlap integral between the coumarin emission and fluorescein absorption, the fluorescein moiety cannot accept the excitation energy of the donor moiety and the donor fluorescence can be observed. After cleavage of the protective groups by hydrolytic enzymes, the fluorescein moiety shows a strong absorption in the coumarin emission region, and then acceptor fluorescence due to FRET is observed. Based on this mechanism, we have developed novel ratiometric fluorescent probes (1-3) for protein tyrosine phosphatase (PTP) activity. They exhibit a large shift in their emission wavelength after reaction with PTPs. The fluorescence quenching problem that usually occurs with FRET probes is overcome by using the coumarin-cyclohexane-fluorescein FRET cassette moiety, in which close contact of the two dyes is hindered. After study of their chemical and kinetic properties, we have concluded that compounds 1 and 2 bearing a rigid cyclohexane linker are practically useful for the ratiometric measurement of PTPs activity. The design concept described in this paper, using FRET switching by spectral overlap integral and a rigid link that prevents close contact of the two dyes, should also be applicable to other hydrolytic enzymes by introducing other appropriate enzyme-cleavable groups into the fluorescein acceptor.
Similar articles
-
Efficient fluorescence resonance energy transfer-based ratiometric fluorescent cellular imaging probe for Zn(2+) using a rhodamine spirolactam as a trigger.Anal Chem. 2010 Apr 15;82(8):3108-13. doi: 10.1021/ac100376a. Anal Chem. 2010. PMID: 20334436
-
Development of FRET-based dual-excitation ratiometric fluorescent pH probes and their photocaged derivatives.Chemistry. 2012 Jan 23;18(4):1247-55. doi: 10.1002/chem.201101434. Epub 2011 Dec 27. Chemistry. 2012. PMID: 22213439
-
A FRET-based approach to ratiometric fluorescence detection of hydrogen peroxide.J Am Chem Soc. 2006 Aug 2;128(30):9640-1. doi: 10.1021/ja063308k. J Am Chem Soc. 2006. PMID: 16866512
-
Design, synthesis and biological application of chemical probes for bio-imaging.Chem Soc Rev. 2010 Jun;39(6):2048-53. doi: 10.1039/b819316a. Epub 2010 Apr 6. Chem Soc Rev. 2010. PMID: 20372693 Review.
-
Photon upconversion in homogeneous fluorescence-based bioanalytical assays.Ann N Y Acad Sci. 2008;1130:188-200. doi: 10.1196/annals.1430.027. Ann N Y Acad Sci. 2008. PMID: 18596348 Review.
Cited by
-
A terbium-based metal-organic framework@gold nanoparticle system as a fluorometric probe for aptamer based determination of adenosine triphosphate.Mikrochim Acta. 2018 Jul 5;185(8):359. doi: 10.1007/s00604-018-2888-1. Mikrochim Acta. 2018. PMID: 29978289
-
How a single-point mutation in horseradish peroxidase markedly enhances enantioselectivity.J Am Chem Soc. 2009 Aug 12;131(31):11155-60. doi: 10.1021/ja903482u. J Am Chem Soc. 2009. PMID: 19610634 Free PMC article.
-
Activatable Optical Probes for the Detection of Enzymes.Curr Org Synth. 2011 Aug;8(4):498-520. doi: 10.2174/157017911796117232. Curr Org Synth. 2011. PMID: 23519774 Free PMC article.
-
Activity-Based Sensing for Chemistry-Enabled Biology: Illuminating Principles, Probes, and Prospects for Boronate Reagents for Studying Hydrogen Peroxide.ACS Bio Med Chem Au. 2022 Dec 21;2(6):548-564. doi: 10.1021/acsbiomedchemau.2c00052. Epub 2022 Oct 11. ACS Bio Med Chem Au. 2022. PMID: 36573097 Free PMC article. Review.
-
Development of fluorescent probes for bioimaging applications.Proc Jpn Acad Ser B Phys Biol Sci. 2010;86(8):837-47. doi: 10.2183/pjab.86.837. Proc Jpn Acad Ser B Phys Biol Sci. 2010. PMID: 20948177 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials