Comparative Study
. 2003 Apr;26(4):1153-7.
doi: 10.2337/diacare.26.4.1153.

The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control

Affiliations
Comparative Study

The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control

Ana Chico et al. Diabetes Care. 2003 Apr.

Abstract

Objective: To evaluate whether the continuous glucose monitoring system (CGMS; MiniMed, Sylmar, CA) is useful for investigating the incidence of unrecognized hypoglycemias in type 1 and type 2 diabetic patients and for improving metabolic control in type 1 diabetic patients.

Research design and methods: A total of 70 diabetic subjects (40 type 1 and 30 type 2 subjects) were monitored using the CGMS. The number of unrecognized hypoglycemias was registered. Furthermore, the 40 type 1 diabetic patients whose treatment was modified in accordance with the information obtained from the CGMS were compared with a control group of 35 different type 1 diabetic patients using intensive capillary glucose measurements. HbA(1c) levels were measured before the monitoring period and 3 months later.

Results: The CGMS detected unrecognized hypoglycemias in 62.5% of the type 1 diabetic patients and in 46.6% of the type 2 diabetic patients. We found that 73.7% of all events occurred at night. HbA(1c) concentrations decreased significantly in both the group of type 1 diabetic subjects monitored with the CGMS (from 8.3 +/- 1.6 to 7.5 +/- 1.2%, P < 0.01) and the control group (from 8.0 +/- 1.4 to 7.5 +/- 0.8%, P < 0.01). The greatest reduction was observed in the subgroup of patients who started continuous subcutaneous insulin infusion therapy, both in the CGMS-monitored and control groups (from 9.4 +/- 2 to 7.2 +/- 1.4% and from 8.1 +/- 1.8 to 7.1 +/- 0.6%, respectively).

Conclusions: The CGMS is useful for detecting unrecognized hypoglycemias in type 1 and type 2 diabetic subjects; however, it is not better than standard capillary glucose measurements for improving metabolic control of type 1 diabetic subjects, regardless of the therapeutic regimen.