Brain fiber tracking with clinically feasible diffusion-tensor MR imaging: initial experience
- PMID: 12668749
- DOI: 10.1148/radiol.2271020313
Brain fiber tracking with clinically feasible diffusion-tensor MR imaging: initial experience
Abstract
Two technical challenges must be overcome before brain fiber tracking with diffusion-tensor magnetic resonance (MR) imaging can be applied to clinical practice: Imaging time must be shortened, and image distortion must be minimized. Single-shot echo-planar MR imaging with parallel imaging technique enabled both objectives to be accomplished. Twenty-three consecutive patients with brain tumors underwent MR imaging with a 1.5-T whole-body MR system. Fiber tracts on the lesion side in the brain had varying degrees of displacement or disruption as a result of the tumor. Tract disruption resulted from direct tumor involvement, compression on the tract, and vasogenic edema surrounding the tumor. This diffusion-tensor MR imaging method with the parallel imaging technique allows clinically feasible brain fiber tracking.
Similar articles
-
Diffusion tensor imaging and optimized fiber tracking in glioma patients: Histopathologic evaluation of tumor-invaded white matter structures.Neuroimage. 2007 Feb 1;34(3):949-56. doi: 10.1016/j.neuroimage.2006.08.051. Epub 2006 Dec 12. Neuroimage. 2007. PMID: 17166744
-
White Matter tract involvement in brain tumors: a diffusion tensor imaging analysis.Surg Neurol. 2009 Nov;72(5):464-9; discussion 469. doi: 10.1016/j.surneu.2009.05.008. Epub 2009 Jul 15. Surg Neurol. 2009. PMID: 19608227
-
Implementation of fiber tract navigation.Neurosurgery. 2006 Apr;58(4 Suppl 2):ONS-292-303; discussion ONS-303-4. doi: 10.1227/01.NEU.0000204726.00088.6D. Neurosurgery. 2006. PMID: 16582653 Clinical Trial.
-
[Fiber tracking by means of magnetic resonance diffusion tensor imaging].Nihon Rinsho. 2004 Apr;62(4):707-14. Nihon Rinsho. 2004. PMID: 15106343 Review. Japanese.
-
Diffusion imaging: insight to cell status and cytoarchitecture.Neuroimaging Clin N Am. 2006 Nov;16(4):619-32, viii-ix. doi: 10.1016/j.nic.2006.06.005. Neuroimaging Clin N Am. 2006. PMID: 17148023 Review.
Cited by
-
Diffusive sensitivity to muscle architecture: a magnetic resonance diffusion tensor imaging study of the human calf.Eur J Appl Physiol. 2004 Dec;93(3):253-62. doi: 10.1007/s00421-004-1186-2. Eur J Appl Physiol. 2004. PMID: 15322853
-
Serial evaluation of diffusion tensor brain fiber tracking in a patient with severe diffuse axonal injury.AJNR Am J Neuroradiol. 2004 Oct;25(9):1553-6. AJNR Am J Neuroradiol. 2004. PMID: 15502137 Free PMC article.
-
A standardised evaluation of pre-surgical imaging of the corticospinal tract: where to place the seed ROI.Neurosurg Rev. 2009 Oct;32(4):445-56. doi: 10.1007/s10143-009-0197-1. Epub 2009 May 13. Neurosurg Rev. 2009. PMID: 19437053
-
Surgical strategy of brain tumors adjacent to the optic radiation using diffusion tensor imaging-based tractography.Oncol Lett. 2010 Nov;1(6):1005-1009. doi: 10.3892/ol.2010.177. Epub 2010 Sep 23. Oncol Lett. 2010. PMID: 22870102 Free PMC article.
-
Oculomotor nerve palsy evaluated by diffusion-tensor tractography.Neuroradiology. 2006 Jun;48(6):434-7. doi: 10.1007/s00234-006-0070-7. Epub 2006 Mar 15. Neuroradiology. 2006. PMID: 16538477
MeSH terms
LinkOut - more resources
Full Text Sources
Medical