Improved alignment method for noisy high-resolution ECG and Holter records using multiscale cross-correlation
- PMID: 12669991
- DOI: 10.1109/TBME.2003.808821
Improved alignment method for noisy high-resolution ECG and Holter records using multiscale cross-correlation
Abstract
The coherent signal averaging process requires accurate estimation of a fiducial point in all beats to be averaged. The temporal cross-correlation between each detected beat and a template beat is the typical alignment method used with high-resolution electrocardiogram (HRECG) records. However, this technique does not produce a precise fiducial mark in records with high noise levels, like those found in Holter HRECG systems. In this study, we propose a new alignment method based on the multiscale cross-correlation between the template and each detected beat. We report the results of tests comparing multiscale and temporal methods for 3000 beats of simulated HRECG records corrupted separately with white noise, electromyographic noise and power line interference (50 Hz) of different root mean square levels. A second study with simulated records constructed from real Holter HRECG records is also presented. The results indicate that the multiscale alignment method produces a lower trigger jitter than the temporal method in all tests. We conclude that the proposed alignment method can be used in HRECG records with high noise levels.
Similar articles
-
Reduction of electromyographic noise in the signal-averaged electrocardiogram by spectral decomposition.IEEE Trans Biomed Eng. 2003 Jan;50(1):114-7. doi: 10.1109/TBME.2002.807317. IEEE Trans Biomed Eng. 2003. PMID: 12617532
-
Alignment methods for averaging of high-resolution cardiac signals: a comparative study of performance.IEEE Trans Biomed Eng. 1991 Jun;38(6):571-9. doi: 10.1109/10.81582. IEEE Trans Biomed Eng. 1991. PMID: 1879846
-
Automated detection and elimination of periodic ECG artifacts in EEG using the energy interval histogram method.IEEE Trans Biomed Eng. 2002 Dec;49(12 Pt 2):1526-33. doi: 10.1109/TBME.2002.805482. IEEE Trans Biomed Eng. 2002. PMID: 12549734 Clinical Trial.
-
[High resolution ECG signals in Chagas patients: SEARCH project].Acta Cient Venez. 1999;50(3):187-94. Acta Cient Venez. 1999. PMID: 10883488 Review. Spanish.
-
Ambulatory electrocardiography signal averaging. Practicalities, clinical value, and potential applications.Cardiol Clin. 1992 Aug;10(3):539-49. Cardiol Clin. 1992. PMID: 1504982 Review.
Cited by
-
Implementation of -Interval fourier transform analysis - Application to compound action potentials.MethodsX. 2023 Oct 21;11:102441. doi: 10.1016/j.mex.2023.102441. eCollection 2023 Dec. MethodsX. 2023. PMID: 38023302 Free PMC article.
-
Cardiomyocyte MEA data analysis (CardioMDA)--a novel field potential data analysis software for pluripotent stem cell derived cardiomyocytes.PLoS One. 2013 Sep 19;8(9):e73637. doi: 10.1371/journal.pone.0073637. eCollection 2013. PLoS One. 2013. PMID: 24069215 Free PMC article.
-
Compressed-Domain ECG-Based Biometric User Identification Using Compressive Analysis.Sensors (Basel). 2020 Jun 9;20(11):3279. doi: 10.3390/s20113279. Sensors (Basel). 2020. PMID: 32526837 Free PMC article.
-
A Review of Automated Methods for Detection of Myocardial Ischemia and Infarction Using Electrocardiogram and Electronic Health Records.IEEE Rev Biomed Eng. 2017;10:264-298. doi: 10.1109/RBME.2017.2757953. Epub 2017 Oct 16. IEEE Rev Biomed Eng. 2017. PMID: 29035225 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources