A method for attenuation and scatter correction of brain SPECT based on computed tomography images
- PMID: 12673170
- DOI: 10.1097/00006231-200304000-00011
A method for attenuation and scatter correction of brain SPECT based on computed tomography images
Abstract
A method for attenuation and scatter correction of brain single photon emission computed tomography (SPECT) is described where computed tomography (CT) images of the brain are used for the calculation of attenuation maps. The method is evaluated for the substance 99mTc hexamethylpropylene amine oxime. A transmission dependent scatter correction is utilized and is based on ray sums calculated through the attenuation map. A method based on external markers is used to align the SPECT and CT image volumes. The markers need only to be present during the SPECT acquisition since the corresponding landmarks can be found without markers on the CT images. The mismatching has been investigated for five patients who have undergone both a CT examination and a SPECT examination with markers. Twelve individuals from the staff have pointed out the landmarks on the CT images, with an average standard deviation of 3.4 mm. Reconstructions with an attenuation map shifted the corresponding 95% confidence interval have been performed to obtain an estimation of the quantitative uncertainty caused by the mismatching, and quantitative errors of up to 6.3% have been measured. At present the method is probably most useful when groups of patients are studied.
Similar articles
-
A study on attenuation correction using Tc-99m external TCT source in Tc-99m GSA liver SPECT.Ann Nucl Med. 2004 Oct;18(7):585-90. doi: 10.1007/BF02984580. Ann Nucl Med. 2004. PMID: 15586632 Clinical Trial.
-
Attenuation correction of myocardial SPECT images with X-ray CT: effects of registration errors between X-ray CT and SPECT.Ann Nucl Med. 2002 Sep;16(6):431-5. doi: 10.1007/BF02990083. Ann Nucl Med. 2002. PMID: 12416584
-
Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT.Ann Nucl Med. 2002 Jun;16(4):255-61. doi: 10.1007/BF03000104. Ann Nucl Med. 2002. PMID: 12126095
-
Single-photon emission computed tomography/computed tomography in brain tumors.Semin Nucl Med. 2007 Jan;37(1):34-47. doi: 10.1053/j.semnuclmed.2006.08.003. Semin Nucl Med. 2007. PMID: 17161038 Review.
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.Semin Nucl Med. 2003 Jul;33(3):166-79. doi: 10.1053/snuc.2003.127307. Semin Nucl Med. 2003. PMID: 12931319 Review.
Cited by
-
Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality.Eur J Nucl Med Mol Imaging. 2014 May;41 Suppl 1:S17-25. doi: 10.1007/s00259-013-2542-4. Epub 2013 Sep 14. Eur J Nucl Med Mol Imaging. 2014. PMID: 24037503
-
Attenuation correction for lung SPECT: evidence of need and validation of an attenuation map derived from the emission data.Eur J Nucl Med Mol Imaging. 2009 Jul;36(7):1076-89. doi: 10.1007/s00259-009-1090-4. Epub 2009 Feb 24. Eur J Nucl Med Mol Imaging. 2009. PMID: 19238381
-
Individual voxelwise dosimetry of targeted 90Y-labelled substance P radiotherapy for malignant gliomas.Eur J Nucl Med Mol Imaging. 2007 Sep;34(9):1388-95. doi: 10.1007/s00259-006-0351-8. Epub 2007 Jan 31. Eur J Nucl Med Mol Imaging. 2007. PMID: 17265035
-
CT-based quantitative SPECT for the radionuclide ²⁰¹Tl: experimental validation and a standardized uptake value for brain tumour patients.Cancer Imaging. 2012;12(1):31-40. doi: 10.1102/1470-7330.2012.0005. Cancer Imaging. 2012. PMID: 22375306 Free PMC article.
-
Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom.Asia Ocean J Nucl Med Biol. 2014 Spring;2(1):24-9. Asia Ocean J Nucl Med Biol. 2014. PMID: 27408856 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical