Methodology for real-time, multianalyte monitoring of fermentations using an in-situ mid-infrared sensor
- PMID: 12673770
- DOI: 10.1002/bit.10618
Methodology for real-time, multianalyte monitoring of fermentations using an in-situ mid-infrared sensor
Abstract
An in-situ, mid-infrared sensor was used to monitor the major analyte concentrations involved in the cultivation of Gluconacetobacter xylinus and the production of gluconacetan, a food-grade exopolysaccharide. To predict the analyte concentrations, three different sets of standard spectra were used to develop calibration models, applying partial least-squares regression. It was possible to build a valid calibration model to predict the 700 spectra collected during the complete time course of the cultivation, using only 12 spectra collected every 10 h as standards. This model was used to reprocess the concentration profiles from 0 to 15 g/L of nine different analytes with a mean standard error of validation of 0.23 g/L. However, this calibration model was not suitable for real-time monitoring as it was probably based on non-specific spectral features, which were correlated only with the measured analyte concentrations. Valid calibration models capable of real-time monitoring could be established by supplementing the set of 12 fermentation spectra with 42 standards of measured analytes. A pulse of 5 g/L ethanol showed the robustness of the model to sudden disturbances. The prediction of the models drifted, however, toward the end of the fermentation. The most robust calibration model was finally obtained by the addition of 34 standard spectra of non-measured analytes. Although the spectra did not contain analyte-specific information, it was believed that this addition would increase the variability space of the calibration model. Therefore, an expanded calibration model containing 88 spectra was used to monitor, in real time, the concentration profiles of fructose, acetic acid, ethanol and gluconacetan and allowed standard errors of prediction of 1.11, 0.37, 0.22, and 0.79 g/L, respectively.
Copyright 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 82: 702-709, 2003.
Similar articles
-
Real-time update of calibration model for better monitoring of batch processes using spectroscopy.Biotechnol Bioeng. 2004 Sep 5;87(5):593-601. doi: 10.1002/bit.20153. Biotechnol Bioeng. 2004. PMID: 15352057
-
Monitoring and control of Gluconacetobacter xylinus fed-batch cultures using in situ mid-IR spectroscopy.J Biotechnol. 2004 Sep 30;113(1-3):231-45. doi: 10.1016/j.jbiotec.2004.03.029. J Biotechnol. 2004. PMID: 15380658
-
Near-infrared spectroscopy: a tool for monitoring submerged fermentation processes using an immersion optical-fiber probe.Appl Spectrosc. 2003 Feb;57(2):132-8. doi: 10.1366/000370203321535024. Appl Spectrosc. 2003. PMID: 14610948
-
Biosensors for real-time in vivo measurements.Biosens Bioelectron. 2005 Jun 15;20(12):2388-403. doi: 10.1016/j.bios.2004.12.003. Epub 2005 Jan 15. Biosens Bioelectron. 2005. PMID: 15854814 Review.
-
Application of near-infrared spectroscopy for monitoring and control of cell culture and fermentation.Biotechnol Prog. 2009 Nov-Dec;25(6):1561-81. doi: 10.1002/btpr.280. Biotechnol Prog. 2009. PMID: 19787698 Review.
Cited by
-
Sensors for disposable bioreactors.Eng Life Sci. 2017 Aug 28;17(8):940-952. doi: 10.1002/elsc.201700049. eCollection 2017 Aug. Eng Life Sci. 2017. PMID: 32624843 Free PMC article. Review.
-
Machine learning for optical chemical multi-analyte imaging : Why we should dare and why it's not without risks.Anal Bioanal Chem. 2023 Jun;415(14):2749-2761. doi: 10.1007/s00216-023-04678-8. Epub 2023 Apr 18. Anal Bioanal Chem. 2023. PMID: 37071140 Free PMC article.
-
Multi-analyte quantification in bioprocesses by Fourier-transform-infrared spectroscopy by partial least squares regression and multivariate curve resolution.Anal Chim Acta. 2014 Jan 7;807:103-10. doi: 10.1016/j.aca.2013.10.042. Epub 2013 Nov 11. Anal Chim Acta. 2014. PMID: 24356226 Free PMC article.
-
Ultrasound-enhanced attenuated total reflection mid-infrared spectroscopy in-line probe: acquisition of cell spectra in a bioreactor.Anal Chem. 2015 Feb 17;87(4):2314-20. doi: 10.1021/ac504126v. Epub 2015 Jan 26. Anal Chem. 2015. PMID: 25582569 Free PMC article.
-
A Hybrid Soft Sensor Approach Combining Partial Least-Squares Regression and an Unscented Kalman Filter for State Estimation in Bioprocesses.Bioengineering (Basel). 2025 Jun 15;12(6):654. doi: 10.3390/bioengineering12060654. Bioengineering (Basel). 2025. PMID: 40564470 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources