Quality of red blood cells using autotransfusion devices: a comparative analysis
- PMID: 12680493
Quality of red blood cells using autotransfusion devices: a comparative analysis
Abstract
Cell salvage devices are routinely used to process and wash red blood cells (RBCs) shed during surgical interventions. Although the principle theory of cell saving is the same, the actual process to achieve this is very different from one device to another. The purpose of this study was to compare the quality of washed, concentrated RBC produced by five very different cell-saving devices, specifically the Cobe BRAT 2, Medtronic Sequestra 1000, Haemonetics Cell Saver 5, Medtronic Autolog, and the Fresenius CATS. Reservoir and washed red blood cells were analyzed for hematocrit (Hct), platelets (PLT), leukocytes (WBC), potassium (K+), heparin, plasma-free hemoglobin (PFH), RBC mass recovery and recovery rate. The Haemonetics and BRAT 2 had the highest RBC recovery. All devices adequately removed heparin and potassium. The Medtronic Autolog had the highest removal of platelets and PFH; whereas, the BRAT had the lowest. Although the Autolog had the highest leukocyte removal, leukocytes were not adequately washed out by any of the autotransfusion devices. In conclusion, although all cell-saving devices use the same theory of centrifugation, the actual quality of the washed RBC product differs widely from one device to another.
Similar articles
-
Quality of red blood cells using the Dideco Electa autotransfusion device.J Extra Corpor Technol. 2005 Mar;37(1):58-9. J Extra Corpor Technol. 2005. PMID: 15804159
-
In vitro comparison of two different methods of cell washing.Perfusion. 2013 Jan;28(1):34-7. doi: 10.1177/0267659112458960. Epub 2012 Aug 30. Perfusion. 2013. PMID: 22936688
-
Comparison of the effects of three cell saver devices on erythrocyte function during cardiopulmonary bypass procedure--a pilot study.Artif Organs. 2012 Oct;36(10):931-5. doi: 10.1111/j.1525-1594.2012.01494.x. Epub 2012 Jul 27. Artif Organs. 2012. PMID: 22835059 Clinical Trial.
-
[Experiences with autologous donation and transfusion equipment].Beitr Infusionsther. 1991;28:274-82. Beitr Infusionsther. 1991. PMID: 1725638 Review. German.
-
[Intra- and postoperative autotransfusion--a quality analysis].Klin Wochenschr. 1988;66 Suppl 15:29-32. Klin Wochenschr. 1988. PMID: 3054284 Review. German.
Cited by
-
Cell salvage is beneficial for all cardiac surgical patients: arguments for and against.J Extra Corpor Technol. 2012 Mar;44(1):P38-41. J Extra Corpor Technol. 2012. PMID: 22730871 Free PMC article.
-
Traditional and emerging technologies for washing and volume reducing blood products.J Blood Med. 2019 Jan 3;10:37-46. doi: 10.2147/JBM.S166316. eCollection 2019. J Blood Med. 2019. PMID: 30655711 Free PMC article. Review.
-
Prolonged EVLP Using OCS Lung: Cellular and Acellular Perfusates.Transplantation. 2017 Oct;101(10):2303-2311. doi: 10.1097/TP.0000000000001616. Transplantation. 2017. PMID: 28009782 Free PMC article.
-
In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System.J Extra Corpor Technol. 2017 Jun;49(2):107-111. J Extra Corpor Technol. 2017. PMID: 28638159 Free PMC article.
-
Quality comparison of autotransfusion devices in cardiac surgery: a prospective observational cohort study.Can J Anaesth. 2025 Mar;72(3):417-425. doi: 10.1007/s12630-024-02893-0. Epub 2025 Feb 4. Can J Anaesth. 2025. PMID: 39904825 English.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Miscellaneous