Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 May;29(5):825-33.
doi: 10.1007/s00134-003-1688-0. Epub 2003 Apr 8.

Detrimental effects of short-term mechanical ventilation on diaphragm function and IGF-I mRNA in rats

Affiliations

Detrimental effects of short-term mechanical ventilation on diaphragm function and IGF-I mRNA in rats

Ghislaine Gayan-Ramirez et al. Intensive Care Med. 2003 May.

Abstract

Objectives: Because respiratory muscle weakness appears to play an important role in weaning from mechanical ventilation, we developed an animal model of mechanical ventilation with appropriate controls in order to determine whether 24 h of mechanical ventilation already affected diaphragmatic function.

Design and interventions: Fifty-two male Wistar rats were randomized into three groups: a non-anesthetized control group (C, n=10), an anesthetized spontaneously breathing group (SB, n=9 out of 26), and an anesthetized and mechanically ventilated group (MV, n=12 out of 16).

Results: After 24 h, in vitro diaphragmatic force was decreased in SB group but even more so in MV group (i.e., 80 Hz: -15% in SB, P<0.005 vs C and -34% in MV group, P<0.005 vs C and SB). This was associated with a significant decrease in the diaphragm type I and type IIa dimensions in the SB group, which was more pronounced in the MV group. Interestingly, diaphragm IGF-I mRNA was decreased in the SB group (-14%, P<0.05 vs C), but more so in MV group (-29%, P<0.001 vs C and P<0.01 vs SB). Moreover, there was a significant correlation between diaphragm force and IGF-I mRNA (at 80 Hz r=0.51, P=0.0056).

Conclusions: We conclude that 24 h of mechanical ventilation in rats, independently of anesthesia, already significantly reduced diaphragm force, fiber dimensions, and its IGF-I mRNA levels.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Physiol. 1999 Aug;277(2 Pt 2):R601-6 - PubMed
    1. Anesth Analg. 1999 Dec;89(6):1557-60 - PubMed
    1. J Am Osteopath Assoc. 2001 Jul;101(7):387-90 - PubMed
    1. Ann Acad Med Singap. 1994 Jul;23(4):566-71 - PubMed

Publication types

LinkOut - more resources