Impact of a modified optic design on visual function: clinical comparative study
- PMID: 12686231
- DOI: 10.1016/s0886-3350(02)01983-1
Impact of a modified optic design on visual function: clinical comparative study
Abstract
Purpose: To determine whether implantation of an intraocular lens (IOL) with a modified anterior surface designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients results in improved pseudophakic quality of vision.
Setting: Department of Ophthalmology, Bundesknappschaft's Hospital, Sulzbach, Germany.
Methods: In an intraindividual randomized study of 45 patients with bilateral cataract, an IOL with a modified anterior surface (Tecnis Z9000, Pharmacia) was compared with a biconvex lens with spherical surfaces (SI-40, Allergan). All patients had bilateral cataract surgery; in 1 eye the Z9000 IOL was implanted and in the other, the SI-40 IOL. After 1 and 3 months, the following investigations were performed: assessment of the anterior and posterior segments including IOL decentration and tilt, pupil size, high- and low-contrast visual acuities, photopic and mesopic contrast sensitivities, and wavefront aberration of the cornea and eye.
Results: Thirty-seven patients were examined at all follow-up visits. Although the eyes with the Z9000 IOL had significantly better best corrected visual acuity after 3 months, the improved quality of vision was more apparent when assessing low-contrast visual acuity and contrast sensitivity. Wavefront measurements revealed no significant spherical aberration in eyes with a Z9000 IOL but significantly positive spherical aberration in eyes with an SI-40 IOL.
Conclusions: The clinical results confirm the theoretical preclinical calculations that the spherical aberration of the eye after cataract surgery can be eliminated by modifying the anterior surface of the IOL. The Tecnis Z9000 lens compensates for the positive spherical aberration in older eyes. This leads to a significant improvement, particularly in contrast sensitivity and mesopic visual quality.
Comment in
-
Aberration-correcting intraocular lenses.J Cataract Refract Surg. 2003 Apr;29(4):627-8. doi: 10.1016/s0886-3350(03)00149-4. J Cataract Refract Surg. 2003. PMID: 12686213 No abstract available.
Similar articles
-
Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery.J Cataract Refract Surg. 2007 Mar;33(3):393-400. doi: 10.1016/j.jcrs.2006.10.066. J Cataract Refract Surg. 2007. PMID: 17321388
-
Spherical aberration and contrast sensitivity after cataract surgery with the Tecnis Z9000 intraocular lens.J Cataract Refract Surg. 2006 Aug;32(8):1320-7. doi: 10.1016/j.jcrs.2006.02.055. J Cataract Refract Surg. 2006. PMID: 16863968 Clinical Trial.
-
Low contrast visual acuity in pseudophakic patients implanted with an anterior surface modified prolate intraocular lens.Acta Ophthalmol Scand. 2004 Dec;82(6):718-22. doi: 10.1111/j.1600-0420.2004.00355.x. Acta Ophthalmol Scand. 2004. PMID: 15606470 Clinical Trial.
-
Wavefront technology in cataract surgery.Curr Opin Ophthalmol. 2004 Feb;15(1):56-60. doi: 10.1097/00055735-200402000-00011. Curr Opin Ophthalmol. 2004. PMID: 14743021 Review.
-
Wavefront-customized intraocular lenses.Curr Opin Ophthalmol. 2004 Aug;15(4):358-64. doi: 10.1097/00055735-200408000-00013. Curr Opin Ophthalmol. 2004. PMID: 15232477 Review.
Cited by
-
Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.Int J Ophthalmol. 2012;5(3):323-8. doi: 10.3980/j.issn.2222-3959.2012.03.14. Epub 2012 Jun 18. Int J Ophthalmol. 2012. PMID: 22773981 Free PMC article.
-
Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery.Clin Ophthalmol. 2011;5:1701-7. doi: 10.2147/OPTH.S21819. Epub 2011 Dec 7. Clin Ophthalmol. 2011. PMID: 22205829 Free PMC article.
-
Evaluation of optical function using a new point spread function analysis system in cataractous and pseudophakic eyes: preliminary results.Jpn J Ophthalmol. 2006 Jan-Feb;50(1):12-9. doi: 10.1007/s10384-005-0275-z. Jpn J Ophthalmol. 2006. PMID: 16453182
-
Star testing: a novel evaluation of intraocular lens optical quality.Br J Ophthalmol. 2006 May;90(5):586-92. doi: 10.1136/bjo.2005.082701. Br J Ophthalmol. 2006. PMID: 16622088 Free PMC article.
-
Comparison of visual outcomes of a diffractive trifocal intraocular lens and a refractive bifocal intraocular lens in eyes with axial myopia: a prospective cohort study.BMC Ophthalmol. 2022 Oct 20;22(1):407. doi: 10.1186/s12886-022-02626-1. BMC Ophthalmol. 2022. PMID: 36266642 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources