Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens
- PMID: 12686234
- DOI: 10.1016/s0886-3350(02)01893-x
Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens
Abstract
Purpose: To analyze techniques of measuring accommodation after implantation of an accommodating posterior chamber intraocular lens (PC IOL).
Setting: Department of Ophthalmology and University Eye Hospital, University Erlangen-Nürnberg, Erlangen, Germany.
Methods: This prospective study analyzed 23 eyes of 23 patients (aged 41 to 87 years) after cataract surgery and PC IOL implantation (1 CU, HumanOptics) 4 weeks and 3 and 6 months after surgery. The results were compared to those in an age-matched control group (n = 20) 6 months after surgery. The following methods were used to measure accommodation: dynamic with objective techniques (PlusOptix PowerRefractor videorefractometry, streak retinoscopy) and subjective techniques (subjective near point [push-up test, accommodometer], defocusing); static with pharmacologic stimulation after pilocarpine 2% eyedrops directly (conventional refractometry); indirectly (change in the anterior chamber depth [ACD] with Zeiss IOLMaster).
Results: Results at 6 months, given as mean +/- SD (range), in the study and control groups, respectively, were as follows: near visual acuity (Birkhäuser reading charts at 35 cm) with distance correction, 0.32 +/- 0.11 (0.20 to 0.60) and 0.14 +/- 0.10 (0.05 to 0.30); accommodation amplitude (diopters) by PowerRefractor, 1.00 +/- 0.44 (0.75 to 2.13) and 0.35 +/- 0.26 (0.10 to 0.65), by retinoscopy, 0.99 +/- 0.48 (0.13 to 2.00) and 0.24 +/- 0.21 (-0.13 to +0.75), by subjective near point, 1.60 +/- 0.55 (0.50 to 2.56) and 0.42 +/- 0.25 (0.00 to 0.75), and by defocusing, 1.46 +/- 0.53 (1.00 to -2.50) and 0.55 +/- 0.33 (0.25 to 0.87). The mean ACD decrease (mm) was 0.78 +/- 0.12 (0.49 to 1.91) and 0.16 +/- 0.09 (0.00 to 0.34) after pilocarpine 2% eyedrops, indicating a mean accommodation of 1.40 D and 0.29 D, respectively, based on Gullstrand's model eye (P =.001). The lowest fluctuation between follow-ups was with the subjective near point and the defocusing techniques followed by ACD decrease with the IOLMaster.
Conclusions: Accommodation after implantation of an accommodating PC IOL should be assessed with several techniques, including subjective and objective, to differentiate true pseudophakic accommodation from pseudoaccommodation. Researchers should be aware of the different variability and consistency of measurements with each technique over time.
Similar articles
-
Theoretical and measured pseudophakic accommodation after implantation of a new accommodative posterior chamber intraocular lens.Arch Ophthalmol. 2003 Dec;121(12):1722-7. doi: 10.1001/archopht.121.12.1722. Arch Ophthalmol. 2003. PMID: 14662592
-
Stability of refraction, accommodation, and lens position after implantation of the 1CU accommodating posterior chamber intraocular lens.J Cataract Refract Surg. 2003 Dec;29(12):2324-9. doi: 10.1016/s0886-3350(03)00413-9. J Cataract Refract Surg. 2003. PMID: 14709293
-
Drug-induced intraocular lens movement and near visual acuity after AcrySof intraocular lens implantation.J Cataract Refract Surg. 2005 Jul;31(7):1298-305. doi: 10.1016/j.jcrs.2004.11.042. J Cataract Refract Surg. 2005. PMID: 16105598
-
Accommodating intraocular lenses: a critical review of present and future concepts.Graefes Arch Clin Exp Ophthalmol. 2007 Apr;245(4):473-89. doi: 10.1007/s00417-006-0391-6. Epub 2006 Aug 30. Graefes Arch Clin Exp Ophthalmol. 2007. PMID: 16944188 Review.
-
Potentially accommodating 1CU intraocular lens: 1-year results in 553 eyes and literature review.J Refract Surg. 2007 Feb;23(2):159-71. doi: 10.3928/1081-597X-20070201-08. J Refract Surg. 2007. PMID: 17326355 Review.
Cited by
-
Accommodation after Nd: YAG capsulotomy in patients with accommodative posterior chamber lens 1CU.Graefes Arch Clin Exp Ophthalmol. 2005 Feb;243(2):120-6. doi: 10.1007/s00417-004-1041-5. Epub 2004 Dec 14. Graefes Arch Clin Exp Ophthalmol. 2005. PMID: 15599585
-
Objective accommodation measurements in prepresbyopic eyes using an autorefractor and an aberrometer.J Cataract Refract Surg. 2008 May;34(5):774-84. doi: 10.1016/j.jcrs.2007.12.033. J Cataract Refract Surg. 2008. PMID: 18471632 Free PMC article.
-
Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness.Ann Transl Med. 2020 Jul;8(14):857. doi: 10.21037/atm-20-187. Ann Transl Med. 2020. PMID: 32793701 Free PMC article.
-
[Evaluation of the valence objective and subjective methods for measuring pseudophakic accommodation].Ophthalmologe. 2013 May;110(5):441-6. doi: 10.1007/s00347-012-2695-8. Ophthalmologe. 2013. PMID: 23053341 German.
-
Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher.J Vis Exp. 2018 Feb 23;(132):57162. doi: 10.3791/57162. J Vis Exp. 2018. PMID: 29553512 Free PMC article.