Rheologic properties of flowable, conventional hybrid, and condensable composite resins
- PMID: 12686294
- DOI: 10.1016/s0109-5641(02)00058-1
Rheologic properties of flowable, conventional hybrid, and condensable composite resins
Abstract
Objectives: This research was undertaken to investigate the viscoelastic properties related to handling characteristics of five commercial flowable, two conventional hybrid and two condensable composite resins and to investigate the effect on the viscosity of filler volume fraction of composites.
Methods: A dynamic oscillatory shear test was used to evaluate the storage shear modulus (G'), loss shear modulus (G"), loss tangent (tan delta) and complex viscosity (eta(*)) of the composite resins as a function of frequency (omega)-dynamic frequency sweep test from 0.01 to 100 rad/s at 25 degrees C-using an Advanced Rheometric Expansion System. To investigate the effect on the viscosity of the composites of the filler volume fraction, the filler weight% and filler volume% were measured by the Archimedes' principle using a pyknometer.
Results: The complex viscosity eta(*) of flowable composites was lower than that of the hybrid composites and significant differences were observed between brands. The complex viscosity eta(*) of condensable composites was higher than that of hybrid composites. The order of complex viscosity eta(*) at omega=10 rad/s in order of decreasing viscosity was as follows, Synergy compact, P-60, Z-250, Z-100, Aeliteflo, Tetric flow, Compoglass flow, Flow it and Revolution. The complex viscosity of flowable composites, normalized with respect to Z-100, was 0.04-0.56 but Synergy compact was 2.158 times higher than that of Z-100. The patterns of the change of loss tangent (tan delta) of the composite resins with increasing frequency were significantly different between brands. Phase angles delta ranged from 30.9 to 78.1 degrees at omega=10 rad/s. All composite resins exhibit pseudoplastic behavior with increasing shear rate. The relationships between the complex shear modulus G(*), the phase angle delta, and the shear rate omega were represented by the frequency domain phasor form, G(*)(omega)=G(*)e(i delta)=G(*) 90 degree angle delta. Only a weak relationship was found between filler volume% and the viscosity of the composite resins.
Significance: This investigation shows that the viscoelasticity of composites in the same class is significantly different between brands. This rheologic property of composite resins influences the handling characteristics of the materials. The locus of frequency domain phasor plots in a complex plane is a valuable method of representing the viscoelastic properties of composite resins.
Similar articles
-
Rheological properties of resin composites according to variations in monomer and filler composition.Dent Mater. 2006 Jun;22(6):515-26. doi: 10.1016/j.dental.2005.05.008. Epub 2005 Sep 19. Dent Mater. 2006. PMID: 16171856
-
Rheological characterization of composites using a vertical oscillation rheometer.Dent Mater. 2007 Apr;23(4):425-32. doi: 10.1016/j.dental.2006.02.013. Epub 2006 Mar 29. Dent Mater. 2007. PMID: 16566997
-
Slumping tendency and rheological properties of flowable composites.Dent Mater. 2010 May;26(5):443-8. doi: 10.1016/j.dental.2010.01.003. Epub 2010 Feb 18. Dent Mater. 2010. PMID: 20170946
-
Packable composites: overview and technical considerations.J Esthet Dent. 1999;11(5):234-49. doi: 10.1111/j.1708-8240.1999.tb00405.x. J Esthet Dent. 1999. PMID: 10825879 Review.
-
Ageing of Dental Composites Based on Methacrylate Resins-A Critical Review of the Causes and Method of Assessment.Polymers (Basel). 2020 Apr 10;12(4):882. doi: 10.3390/polym12040882. Polymers (Basel). 2020. PMID: 32290337 Free PMC article. Review.
Cited by
-
The Effect of the Initiator/Activator/Accelerator Ratio on the Degree of Conversion, Film Thickness, Flow, and Cytotoxicity of Dual-Cured Self-Adhesive Resin Cements.Materials (Basel). 2024 Jul 19;17(14):3572. doi: 10.3390/ma17143572. Materials (Basel). 2024. PMID: 39063864 Free PMC article.
-
A comparative evaluation of microleakage of restorations using silorane-based dental composite and methacrylate-based dental composites in Class II cavities: An in vitro study.J Pharm Bioallied Sci. 2016 Oct;8(Suppl 1):S81-S85. doi: 10.4103/0975-7406.191975. J Pharm Bioallied Sci. 2016. PMID: 27829753 Free PMC article.
-
Effect of Pre-heating on Microtensile Bond Strength of Composite Resin to Dentin.J Dent (Tehran). 2014 Sep;11(5):569-75. Epub 2014 Sep 30. J Dent (Tehran). 2014. PMID: 25628684 Free PMC article.
-
Comparative evaluation of Rheological characteristics of Giomers and other Nano-flowable resin composites in vitro.Biomater Investig Dent. 2021 Nov 8;8(1):170-179. doi: 10.1080/26415275.2021.1996239. eCollection 2021. Biomater Investig Dent. 2021. PMID: 34778794 Free PMC article.
-
A 1-year comparative evaluation of clinical performance of nanohybrid composite with Activa™ bioactive composite in Class II carious lesion: A randomized control study.J Conserv Dent. 2019 Jan-Feb;22(1):92-96. doi: 10.4103/JCD.JCD_511_18. J Conserv Dent. 2019. PMID: 30820090 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources