Comparative Study
. 2003 Mar;10(2):94-8.
doi: 10.1155/2003/792917.

Effects of positive end-expiratory pressure on oscillated volume during high frequency chest compression in children with cystic fibrosis

Affiliations
Free article
Comparative Study

Effects of positive end-expiratory pressure on oscillated volume during high frequency chest compression in children with cystic fibrosis

Cara F Dosman et al. Can Respir J. 2003 Mar.
Free article

Abstract

Objective: To investigate the effects of positive end-expiratory pressure (PEEP) on end-expiratory lung volume (EELV) and mean oscillated volume (V(osc)) during high frequency chest compression (HFCC).

Design: A clinic-based prospective intervention study.

Setting: Pulmonary function laboratory, University of Alberta, Edmonton, Alberta.

Population: Nine children with cystic fibrosis with little or no obstructive airway disease who were selected from the outpatient Cystic Fibrosis and Pediatric Pulmonary Clinics at the University of Alberta Hospital, Edmonton, Alberta.

Methods: Each child received HFCC alone (at 10 Hz with chest wall pressure of 8 cm H2O) and HFCC plus PEEP. A closed circuit spirometry system was used to measure HFCC- and PEEP-induced changes in EELV, expressed as per cent baseline functional residual capacity (FRC) measured using helium dilution. An isothermic chamber permitted measurement of V(osc).

Results: HFCC caused a significant 9% decrease in EELV. Adding 2.0 +/- 0.3 cm H2O of PEEP increased EELV back to at least the FRC level. With HFCC alone, Vosc was significantly lower during spontaneous expiration than during spontaneous inspiration, but adding PEEP to HFCC increased V(osc), especially during spontaneous expiration.

Conclusions: Adding PEEP during HFCC prevents the decrease in EELV and increases V(osc). Therefore, PEEP may improve HFCC-induced mucus clearance in children with cystic fibrosis.

PubMed Disclaimer

Publication types

LinkOut - more resources