Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey
- PMID: 12687286
- DOI: 10.1007/s00330-003-1883-y
Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey
Abstract
Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case.
Similar articles
-
[Radiation exposure of the head, midface and pelvis in multi-slice CT (MSCT): comparison with single-slice CT (SSCT)].Rofo. 2003 Feb;175(2):234-8. doi: 10.1055/s-2003-37242. Rofo. 2003. PMID: 12584624 German.
-
Effective doses in standard protocols for multi-slice CT scanning.Eur Radiol. 2003 May;13(5):1148-53. doi: 10.1007/s00330-002-1614-9. Epub 2002 Jul 27. Eur Radiol. 2003. PMID: 12695839
-
Very low-dose coronary artery calcium scanning with high-pitch spiral acquisition mode: comparison between 120-kV and 100-kV tube voltage protocols.J Cardiovasc Comput Tomogr. 2013 Jan-Feb;7(1):32-8. doi: 10.1016/j.jcct.2012.11.004. Epub 2012 Dec 1. J Cardiovasc Comput Tomogr. 2013. PMID: 23333186
-
Pushing the envelope: new computed tomography techniques for cardiothoracic imaging.J Thorac Imaging. 2010 May;25(2):100-11. doi: 10.1097/RTI.0b013e3181d7e898. J Thorac Imaging. 2010. PMID: 20463530 Review.
-
Importance in optimization of multi-slice computed tomography scan protocols.Australas Radiol. 2006 Jun;50(3):278-85. doi: 10.1111/j.1440-1673.2006.01579.x. Australas Radiol. 2006. PMID: 16732832 Review.
Cited by
-
Evaluation of the response to treatment of solid tumours - a consensus statement of the International Cancer Imaging Society.Br J Cancer. 2004 Jun 14;90(12):2256-60. doi: 10.1038/sj.bjc.6601843. Br J Cancer. 2004. PMID: 15150551 Free PMC article. Review.
-
Body Composition in Pediatric Solid Tumors: State of the Science and Future Directions.J Natl Cancer Inst Monogr. 2019 Sep 1;2019(54):144-148. doi: 10.1093/jncimonographs/lgz018. J Natl Cancer Inst Monogr. 2019. PMID: 31532526 Free PMC article. Review.
-
Dose reduction and image quality in CT angiography for cerebral aneurysm with various tube potentials and current settings.Br J Radiol. 2012 Sep;85(1017):e673-81. doi: 10.1259/bjr/63268088. Epub 2012 Jan 17. Br J Radiol. 2012. PMID: 22253346 Free PMC article.
-
National Survey of Radiation Dose and Image Quality in Adult CT Head Scans in Taiwan.PLoS One. 2015 Jun 30;10(6):e0131243. doi: 10.1371/journal.pone.0131243. eCollection 2015. PLoS One. 2015. PMID: 26125549 Free PMC article.
-
Gender Differences in the Impact of Recommendations on Diagnostic Imaging Tests: A Retrospective Study 2007-2021.Life (Basel). 2023 Jan 20;13(2):289. doi: 10.3390/life13020289. Life (Basel). 2023. PMID: 36836646 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources