Multi-component immunoaffinity subtraction chromatography: an innovative step towards a comprehensive survey of the human plasma proteome
- PMID: 12687610
- DOI: 10.1002/pmic.200390057
Multi-component immunoaffinity subtraction chromatography: an innovative step towards a comprehensive survey of the human plasma proteome
Abstract
In order to discover novel protein markers indicative of disease processes or drug effects, the proteomics technology platform most commonly used consists of high resolution protein separation by two-dimensional electrophoresis (2-DE), mass spectrometric identification of proteins from stained gel spots and a bioinformatic data analysis process supported by statistics. This approach has been more successful in profiling proteins and their disease- or treatment-related quantitative changes in tissue homogenates than in plasma samples. Plasma protein display and quantitation suffer from several disadvantages: very high abundance of a few proteins; high heterogeneity of many proteins resulting in long charge trains; crowding of 2-DE separated protein spots in the molecular mass range between 45-80 kD and in the isoelectric point range between 4.5 and 6. Therefore, proteomic technologies are needed that address these problems and particularly allow accurate quantitation of a larger number of less abundant proteins in plasma and other body fluids. The immunoaffinity-based protein subtraction chromatography (IASC) described here removes multiple proteins present in plasma and serum in high concentrations effectively and reproducibly. Applying IASC as an upfront plasma sample preparation process for 2-DE, the protein spot pattern observed in gels changes dramatically and at least 350 additional lower abundance proteins are visualized. Affinity-purified polyclonal antibodies (pAbs) are the immunoaffinity reagents used to specifically remove the abundant proteins such as albumin, immunoglobulin G, immunoglobulin A, transferrin, haptoglobin, alpha-1-antitrypsin, hemopexin, transthyretin, alpha-2-HS glycoprotein, alpha-1-acid glycoprotein, alpha-2-macroglobulin and fibrinogen from human plasma samples. To render the immunoaffinity subtraction procedure recyclable, the pAbs are immobilized and cross-linked on chromatographic matrices. Antibody-coupled matrices specific for one protein each can be pooled to form mixed-bed IASC columns. We show that up to ten affinity-bound plasma proteins with similar solubility characteristics are eluted from a mixed-bed column in one step. This facilitates automated chromatographic processing of plasma samples in high throughput, which is desirable in proteomic disease marker discovery projects.
Similar articles
-
Rat plasma proteomics: effects of abundant protein depletion on proteomic analysis.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Apr 15;849(1-2):273-81. doi: 10.1016/j.jchromb.2006.11.051. Epub 2006 Dec 22. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17188586
-
Intact-protein-based high-resolution three-dimensional quantitative analysis system for proteome profiling of biological fluids.Mol Cell Proteomics. 2005 May;4(5):618-25. doi: 10.1074/mcp.M400126-MCP200. Epub 2005 Feb 9. Mol Cell Proteomics. 2005. PMID: 15703445
-
Limitation of immunoaffinity column for the removal of abundant proteins from plasma in quantitative plasma proteomics.Biomed Chromatogr. 2009 May;23(5):480-7. doi: 10.1002/bmc.1139. Biomed Chromatogr. 2009. PMID: 19039805
-
Emerging Affinity-Based Proteomic Technologies for Large-Scale Plasma Profiling in Cardiovascular Disease.Circulation. 2017 Apr 25;135(17):1651-1664. doi: 10.1161/CIRCULATIONAHA.116.025446. Circulation. 2017. PMID: 28438806 Free PMC article. Review.
-
IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomics biomarker discovery.Methods. 2012 Feb;56(2):246-53. doi: 10.1016/j.ymeth.2011.09.001. Epub 2011 Sep 10. Methods. 2012. PMID: 21925605 Free PMC article. Review.
Cited by
-
Multiplexed, Quantitative Workflow for Sensitive Biomarker Discovery in Plasma Yields Novel Candidates for Early Myocardial Injury.Mol Cell Proteomics. 2015 Sep;14(9):2375-93. doi: 10.1074/mcp.M114.046813. Epub 2015 Feb 27. Mol Cell Proteomics. 2015. PMID: 25724909 Free PMC article.
-
A preliminary method development study to identify potential stroke biomarkers in plasma using multiple chromatographies with nanoLC-ESIMS detection.J Neural Transm (Vienna). 2013 Oct;120(10):1441-5. doi: 10.1007/s00702-013-1018-9. Epub 2013 Apr 13. J Neural Transm (Vienna). 2013. PMID: 23580158 Free PMC article.
-
Vinyl sulfone silica: application of an open preactivated support to the study of transnitrosylation of plant proteins by S-nitrosoglutathione.BMC Plant Biol. 2013 Apr 12;13:61. doi: 10.1186/1471-2229-13-61. BMC Plant Biol. 2013. PMID: 23586608 Free PMC article.
-
Depletion of abundant plasma proteins and limitations of plasma proteomics.J Proteome Res. 2010 Oct 1;9(10):4982-91. doi: 10.1021/pr100646w. J Proteome Res. 2010. PMID: 20677825 Free PMC article.
-
Candidate-based proteomics in the search for biomarkers of cardiovascular disease.J Physiol. 2005 Feb 15;563(Pt 1):23-60. doi: 10.1113/jphysiol.2004.080473. Epub 2004 Dec 20. J Physiol. 2005. PMID: 15611012 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials