Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Apr;110(4):772-80.
doi: 10.1016/S0161-6420(02)01980-2.

Quantification of posterior capsule opacification with round and sharp edge intraocular lenses

Affiliations
Comparative Study

Quantification of posterior capsule opacification with round and sharp edge intraocular lenses

Gerd U Auffarth et al. Ophthalmology. 2003 Apr.

Abstract

Purpose: To quantitatively evaluate and compare intraocular lenses (IOLs) with a round or sharp optic edge design for posterior capsule opacification (PCO).

Study design: Prospective comparative observational case series. PARTICIPANTS/MATERIALS: Photographs from 174 eyes were analyzed for PCO at the Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany.

Main outcome measures: Part I: 121 eyes of 121 patients were analyzed for quantification of PCO. IOLs evaluated were Corneal ACR6 (n = 21), Alcon Acrysof (n = 20), Allergan AR40 (n = 27), Pharmacia 811 one-piece polymethyl methacrylate (PMMA) IOL (n = 24), and Pharmacia 911A silicone IOL (n = 29). Mean follow-up was 14.01 +/- 2.81 months; mean patient age was 73.2 +/- 7.3 years. The morphologic PCO formation was evaluated for the entire optic and in the central 3-mm zone. Part II: In 53 eyes of 46 patients aged 73.4 +/- 10.8 years with an Alcon Acrysof IOL, PCO formation and capsulorrhexis/optic overlapping were analyzed 34.2 +/- 4 months after cataract surgery using EPCO Software.

Results: Part I: The PCO values of the entire optic were for Corneal ACR6, 1.93 +/- 0.62; PMMA, 0.64 +/- 0.63; AR40, 0.55 +/- 0.28; Alcon Acrysof, 0.145 +/- 0.27; and 0.161 +/- 0.181 for the Pharmacia 911A IOL (P < 0.01). The PCO values of the central 3-mm zone were for Corneal ACR6, 1.64 +/- 0.96; PMMA, 0.49 +/- 0.39; AR40, 0.22 +/- 0.32; Alcon Acrysof, 0.08 +/- 0.21; and 0.06 +/- 0.11 for the Pharmacia 911A IOL (P < 0.01). Part II: Average overlapping of capsulorrhexis and Acrysof IOL optic was 40.5% +/- 12.4%. There was a significant correlation between PCO values and overlapping (r = -0.69, P < 0.001).

Conclusions: The sharp-edge IOL types (Alcon Acrysof and Pharmacia 911A silicone IOL) resulted in statistically significantly lower PCO values for analysis of the entire optic area and central 3-mm zone. There was no statistically significant difference in PCO values between the two sharp-edge optic IOLs. An overlapping of capsulorrhexis rim and the anterior IOL optic surface of more than 20% resulted in significantly lower PCO values with the Acrysof IOL.

PubMed Disclaimer

Publication types

LinkOut - more resources