Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography
- PMID: 12691409
- DOI: 10.3171/jns.2003.98.4.0828
Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography
Abstract
Object: The goal of this study was to assess the diagnostic accuracy of computerized tomography (CT) angiography performed with the aid of multislice technology (MSCT angiography) in the investigation of intracranial aneurysms, by comparing this method with intraarterial digital subtraction (IADS) angiography.
Methods: Fifty consecutive adult patients, who successively underwent MSCT angiography (four rows) and IADS angiography of intracranial vessels, were prospectively identified. The MSCT angiography studies consisted of 1.25-mm slices, with 0.8-mm reconstruction intervals, a pitch of 0.75, and timing determined by a test bolus. Two neuroradiologists, who were blinded to the initial interpretation of the MSCT angiograms as well as to those of the IADS angiograms, independently reviewed the MSCT angiograms for the detection and characterization of intracranial aneurysms. Forty-nine intracranial aneurysms were identified in 40 patients; 33 of these lesions were responsible for subarachnoid hemorrhage. The sensitivity, specificity, and accuracy of MSCT angiography in the detection of intracranial aneurysms were 94.8, 95.2, and 94.9%, respectively, on a per-aneurysm basis and 99, 95.2, and 98.3%, respectively, on a per-patient basis. Interobserver agreement was 98%. There was an excellent correlation between aneurysm size assessed using MSCT angiography and that determined by IADS angiography (slope = 0.916, r = 0.877, p < 0.001); however, 2 mm stood as the cutoff size below which the sensitivity of MSCT angiography was statistically lower. That method displayed great accuracy in characterizing the morphological characteristics of the aneurysm.
Conclusions: Multislice CT angiography is an accurate and robust noninvasive screening test for intracranial aneurysms. It performs better than that reported for single-slice CT angiography. Introduction of eight- and especially 16-row MSCT angiography will provide further progression through thinner slices, a lower pitch, and a purely arterial phase.
Similar articles
-
Comparison of multislice computerized tomography angiography and digital subtraction angiography in the postoperative evaluation of patients with clipped aneurysms.J Neurosurg. 2006 Mar;104(3):395-403. doi: 10.3171/jns.2006.104.3.395. J Neurosurg. 2006. PMID: 16572652 Clinical Trial.
-
Accuracy of 16-row multislice computerized tomography angiography for assessment of intracranial aneurysms.Surg Neurol. 2009 Jan;71(1):32-42. doi: 10.1016/j.surneu.2007.08.005. Epub 2008 Oct 18. Surg Neurol. 2009. PMID: 18930311
-
Sixteen-row multislice computed tomography angiography in the diagnosis and characterization of intracranial aneurysms: comparison with conventional angiography and intraoperative findings.J Neurosurg. 2008 Jun;108(6):1184-91. doi: 10.3171/JNS/2008/108/6/1184. J Neurosurg. 2008. PMID: 18518726 Clinical Trial.
-
Computed tomography angiography for the detection and characterization of intra-cranial aneurysms: current status.Clin Radiol. 2005 Dec;60(12):1221-36. doi: 10.1016/j.crad.2005.06.007. Clin Radiol. 2005. PMID: 16291304 Review.
-
Diagnostic accuracy of multislice CT angiography in peripheral arterial disease.J Vasc Interv Radiol. 2006 Dec;17(12):1915-21. doi: 10.1097/01.RVI.0000248830.17550.50. J Vasc Interv Radiol. 2006. PMID: 17185686 Review.
Cited by
-
Dynamic 3D-CT angiography.AJNR Am J Neuroradiol. 2007 Feb;28(2):299-304. AJNR Am J Neuroradiol. 2007. PMID: 17296999 Free PMC article.
-
Endovascular minimally invasive treatment of the intracranial aneurysms--first 124 cases.J Med Life. 2012 Sep 15;5(3):360-6. Epub 2012 Sep 25. J Med Life. 2012. PMID: 23049642 Free PMC article.
-
Minimizing clip artifacts in multi CT angiography of clipped patients.AJNR Am J Neuroradiol. 2006 Jan;27(1):60-6. AJNR Am J Neuroradiol. 2006. PMID: 16418357 Free PMC article.
-
Cerebrovascular disease.AJNR Am J Neuroradiol. 2007 Jun-Jul;28(6):1197-9. AJNR Am J Neuroradiol. 2007. PMID: 17569987 Free PMC article. Review. No abstract available.
-
Current diagnostic approaches to subarachnoid haemorrhage.Eur Radiol. 2005 Jun;15(6):1135-47. doi: 10.1007/s00330-005-2665-5. Epub 2005 Feb 12. Eur Radiol. 2005. PMID: 15711840 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical