Value and limitations of an inverse solution for two equivalent dipoles in localising dual accessory pathways
- PMID: 12691432
- DOI: 10.1007/BF02344880
Value and limitations of an inverse solution for two equivalent dipoles in localising dual accessory pathways
Abstract
Investigations were carried out into whether an equivalent generator consisting of two dipoles could be used to detect dual sites of ventricular activity. A computer model of the human ventricular myocardium was used to simulate activation sequences initiated at eight different pairs of sites positioned on the epicardial surface of the atrio-ventricular ring. From these sequences, 117-lead body surface potentials (covering the anterior and posterior torso), 64-lead magnetic field maps (above the anterior chest) and 128-lead magnetic field maps (above the anterior and posterior chest) were simulated and were then used to localise dual accessory pathways employing pairs of equivalent dipoles. Average localisation errors were 12 mm, 12 mm and 9 mm, respectively, when body surface potentials, 64-lead and 128-lead magnetic fields were used. The results of the study suggest that solving the inverse problem for two dipoles could provide additional information on dual accessory pathways prior to electrophysiological study.
Similar articles
-
Accuracy of single-dipole inverse solution when localising ventricular pre-excitation sites: simulation study.Med Biol Eng Comput. 1998 May;36(3):323-9. doi: 10.1007/BF02522478. Med Biol Eng Comput. 1998. PMID: 9747572
-
Spatial resolution of body surface potential maps and magnetic field maps: a simulation study applied to the identification of ventricular pre-excitation sites.Med Biol Eng Comput. 1998 Mar;36(2):145-57. doi: 10.1007/BF02510736. Med Biol Eng Comput. 1998. PMID: 9684453
-
Determination of the site of the accessory pathway in WPW syndrome by an electrocardiographic inverse solution.Jpn Heart J. 1990 Nov;31(6):777-87. doi: 10.1536/ihj.31.777. Jpn Heart J. 1990. PMID: 2084275
-
[Ventricular pre-excitation: electrophysiopathology, criteria for interpretation and clinical diagnosis. References for geriatrics].Minerva Cardioangiol. 2001 Feb;49(1):47-73. Minerva Cardioangiol. 2001. PMID: 11279385 Review. Italian.
-
The inverse problem in electrocardiography: solutions in terms of equivalent sources.Crit Rev Biomed Eng. 1988;16(3):171-214. Crit Rev Biomed Eng. 1988. PMID: 3064970 Review.
Cited by
-
Equivalent moving dipole localization of cardiac ectopic activity in a swine model during pacing.IEEE Trans Inf Technol Biomed. 2010 Nov;14(6):1318-26. doi: 10.1109/TITB.2010.2051448. Epub 2010 May 27. IEEE Trans Inf Technol Biomed. 2010. PMID: 20515710 Free PMC article.
-
Assessment of regularization techniques for electrocardiographic imaging.J Electrocardiol. 2014 Jan-Feb;47(1):20-8. doi: 10.1016/j.jelectrocard.2013.10.004. Epub 2013 Oct 17. J Electrocardiol. 2014. PMID: 24369741 Free PMC article.